4.2.3.   C

ONNECTION MODE

 

 
I)  

+CLINO PLUS+ (Compatibility) – MODE 

 
 
Polling mode 

  Pressing SELECT/PRINT Key will send response 

  Receiving (ASCII Character ‚H‘) will bring instrument to HOLD-MODE. 

  Receiving (ASCII Character ‚P‘) will send data to port (response) 

 
 
Timing of data exchange 

  Immediately after receiving command, response will be sent. 

  During the data transmission (response) the open drain signal (RTS) will be held low 

 
Used data frame 
Frame characters:   (All ASCII - Characters) 

 

 

 
 

II)  

+CLINO PLUS+ -Mode 

 
Character set 

  ASCII Numbers  ‚0‘ .. ‚9‘            

  ASCII Letters ‚A‘ .. ‚F‘ 

  ASCII Special characters ‚~‘  

  ASCII Control characters <CR> 

 
 
Polling mode 

  Instrument will not transmit any data spontaneously 

  Instrument will transmit a response only upon reception of a command  

  The same data frame structure is used for commands as well as responses 

 
 
Timing of data exchange 

  A request may be sent to the instrument with max. rate or with large intervals between the individual 

characters. 

  Immediately after receiving (<CR>, = carriage return) of command, response will be sent.  

  During the data transmission (response) the open drain signal (RTS) will be held low  

Summary of Contents for Clinotronic PLUS

Page 1: ...ölderli CH 8405 WINTERTHUR Switzerland Tel 0041 0 52 233 66 66 Fax 0041 0 52 233 20 53 Homepage http www wylerag com E Mail wyler wylerag com OPERATOR S MANUAL The intelligent universal inclinometer File clino_e doc ...

Page 2: ...NT 12 3 2 RELATIVE MEASUREMENT 12 3 3 MEASUREMENT OF WIDE ANGLES 3 4 SWITCHING OFF 13 4 TECHNICAL SPECIFICATIONS 14 4 1 GENERAL 14 4 2 SPECIFICATIONS FOR PORT CONNECTION 14 5 SERVICE 17 5 1 CALIBRATION 17 5 2 ACCESSORIES SPARE PARTS 18 6 STORAGE CARE AND HANDLING OF THE BATTERIES 18 APPENDIX A Connecting wiring diagrams 19 APPENDIX B Attaching CLINO PLUS 22 APPENDIX C CLINOMASTER for the calibrati...

Page 3: ...pendix A 20 Connecting the CLINO PLUS to a computer with a CMOS 5V interface Appendix A 21 Connecting the CLINO PLUS to a computer with a RS232 interface using Appendix A 20 Connecting the CLINO PLUS to a computer with a RS232 interface using Appendix A 20 Connecting the CLINO PLUS to a computer with a RS422 interface using Appendix A 21 Connecting the CLINO PLUS to a computer with a RS422 interfa...

Page 4: ...s 5 2 18 Measuring units 2 2 7 Measuring units 2 6 10 O ON MODE key 2 1 6 ON MODE key 2 2 7 Operating elements 2 6 Operating instructions 1 3 5 P Print Function 2 9 11 R Relative measurement 3 2 12 Repair of Measuring Instruments Appendix D 24 Reset 2 11 12 Resolution 4 1 14 S SELECT PRINT key 2 1 6 SELECT PRINT key 2 2 7 Selection pointer for operation modes 2 2 7 Service 5 17 Set absolute zero 2...

Page 5: ...operating elements and the interface socket The CLINO PLUS provides a measuring capacity of 45 degree upon requirement delivery is also possible with a measuring range of 10 or 30 degrees Four precisely machined surfaces assure accuracy and repeatability of measurements Selectable by push button any units suitable for inclination may be applied to the display Even slope indication based on a relat...

Page 6: ... KEY ECHO Visual indication a key is depressed 5 Indication of direction of inclination 7 Battery indicator Visible only in case of low battery 4 Selection pointer for operation modes Attention Whilst trying out the different functions be careful never to operate the two bottom keys ENTER HOLD and SELECT PRINT simultaneously This would result in the loss of calibration data This combination is pro...

Page 7: ...ce made by using the SELECT key 2 ENTER HOLD Key Use this key to freeze a measurement value The hold function is particularly useful if measurements have to be taken when the display is not visible The CLINO PLUS will pause until two identical values are detected in succession self sensing for motion The valid indication will be displayed with flashing figures Delete the indication by re selecting...

Page 8: ...orrect any value Incline the CLINO PLUS to the right The following displays are correct any value The CLINO PLUS persistently indicates flashing means that no calibration data is available Data was probably lost or destroyed by accidentally calling the calibration utility The CLINO PLUS must be recalibrated See chapter 5 1 for calibration procedure For possible salvation see chapter 2 10 2 5 SET A...

Page 9: ...ration at the measuring location largely influences the time necessary to collect a valid measurement Heavy vibration may even completely prevent the condition two identical values in succession necessary to register a true measurement In order to regain measuring capability under this condition take the CLINO PLUS to an object with a lower vibration level and complete the operation in process By ...

Page 10: ...he key ON MODE align the selection pointer with the indication REL BASE Now use the key SELECT PRINT to display the length presently stored Repeated use of SELECT PRINT will in turn display the values stored in the mm and in the inch memory With the desired display note unit indicated mm m for length in mm 10 for length in inch use the key ENTER HOLD to open the memory for alteration The selection...

Page 11: ...onnected peripheral instrument Without a connection the HOLD mode will be cancelled The level of vibration at the measuring location considerably influences the time necessary to collect a valid measurement Severe vibration may even completely prevent the condition two identical values in succession necessary to register a true measurement In order to regain measuring capability under this conditi...

Page 12: ...2 12 DATA TRANSMISSION True RS485 Interface connections to various WYLER instruments such as e g Levelmeter 2000 WYLER T C as well as to a RS 232 com port of a PC Special WYLER connector required 3 APPLICATIONS 3 1 ABSOLUTE MEASUREMENT For accurate measurements it is advisable to reset the absolute zero point of the CLINO PLUS in accordance with chapter 2 5 prior to first measurement Thereafter pl...

Page 13: ...t any angle greater than the sensor measuring capacity 45 Deg Vertical and horizontal measurements Measurements with the different bases Declined to the right Inclined to the right Inclined to the right Inclined slightly to the right 3 4 SHUT OFF THE INSTRUMENT To shut off the instrument press the ON MODE key for min 3 seconds until the display is empty Remarks When an external power supply is con...

Page 14: ...arity 9600 Baud Battery Batterie 1 x Size AA 1 5V Alkaline or 1 x Size AA 3 0V MnO2 Lithium Battery life Betriebsdauer In full operation Vollbetrieb Size AA 1 5V Alkaline 130 hrs Size AA 3 0V MnO2 Lithium 300 hrs Housing Gehäuse Aluminium hard anodised 100 x 75 x 30 mm Weight Gewicht 485 g incl Battery Temp range Temp Bereich Operating Storage 0 to 40 C 20 to 70 C CE conformity Emission Immunity f...

Page 15: ...haracters All ASCII Characters II CLINO PLUS Mode Character set ASCII Numbers 0 9 ASCII Letters A F ASCII Special characters ASCII Control characters CR Polling mode Instrument will not transmit any data spontaneously Instrument will transmit a response only upon reception of a command The same data frame structure is used for commands as well as responses Timing of data exchange A request may be ...

Page 16: ...nstruments resp sensor address ASCII 0 9 A F Bit 3 0 ASCII 1 Opcode ASCII 0 9 A F Bit 3 0 Data ASCII 0 9 A F Bit 31 28 ASCII 0 9 A F Bit 27 24 ASCII 0 9 A F Bit 23 20 ASCII 0 9 A F Bit 19 16 ASCII 0 9 A F Bit 15 12 ASCII 0 9 A F Bit 11 8 ASCII 0 9 A F Bit 7 4 ASCII 0 9 A F Bit 3 0 CheckSum ASCII 0 9 A F Bit 7 4 ASCII 0 9 A F Bit 3 0 Trailer ASCII CR End of command or response Examples to CLINO PLU...

Page 17: ...ss the two keys ON MODE and ENTER HOLD by starting with the ON MODE key for a min period of 1 sec Start the calibration program by pressing first the key SELECT PRINT and keep pressed while using simultaneously the key ENTER HOLD for a period of min 5 seconds A successful start to the calibration program is indicated by the display showing at first 00 00 thereafter displaying in flashing mode whic...

Page 18: ...of storage never place the CLINO PLUS in a position with it s longitudinal axis vertical An incorrect storage position may due to overloading of the pendulum system result in a substantial drift of the zero point whilst recovering its equilibrium 6 2 CARE AND HANDLING OF THE BATTERIES Read the instructions in your manual before installing batteries Make sure to insert the batteries properly follow...

Page 19: ...INO PLUS using the RS485 interface b Connecting the CLINO PLUS to a computer with a RS485 interface using the RS485 interface of the instrument c Connecting the CLINO PLUS to a computer with a RS485 interface using the RS485 interface of the instrument also a remote button installed ...

Page 20: ...arks Cable and interface connector can be ordered from the nearest distributor or from WYLER AG e Connecting the CLINO PLUS to a computer with a RS232 interface using the RS485 interface of the instrument also a remote button installed f Connecting the CLINO PLUS to a computer with a CMOS 5V interface using the RS485 interface of the instrument ...

Page 21: ...ting the CLINO PLUS to a computer with a CMOS 5V interface using the RS485 interface of the instrument also a remote button installed h Connecting the CLINO PLUS to a computer with a RS422 interface using the RS485 interface of the instrument ...

Page 22: ...a remote button installed APPENDIX B Attaching CLINO PLUS Special executions with permanent magnets recessed in the measuring bases are available on request During manufacturing threaded holes may be put in at the same time These options may result in higher cost and longer delivery time Standard dimensions for magnetic inserts and threaded holes ...

Page 23: ...ALIBRATION CLINOMASTER is the solution when the tracing of the calibration data of the CLINOTRONIC instrument is required CLINOMASTER is equipped with 21 accurately positioned calibration points in 5 deg steps CLINOMASTER makes the checking of the instruments measuring accuracy remarkably easy and reliable CLINOMASTER is the perfect master for the calibration of the CLINOTRONIC CLINOMASTER and CLI...

Page 24: ... quote up to 65 of the price for a new instrument o suitable packing for air transport o expenses of the ERS In case the customer decides to use the ERS the customer informs the local WYLER partner or directly WYLER SWITZERLAND providing the necessary data The customer will receive all information and instructions necessary for a smooth handling the customer has just to pack the product suitably a...

Reviews: