WASTE WATER PUMPING SYSTEMS
Wykamol SumpFlo
™
31/44
Installation and operating guidelines
Technical advice: 0845 400 6666
www.wykamol.com
5. Dimensions
5.1 Chamber
Model
All models
Diameter
600mm
Height
600mm
5.2 High level alarm (9V)
Model
High level alarm
Height
90mm
Width
90mm
Depth
30mm
5.3 Battery backup panel
Model
BBPS
Height
380mm
Width
300mm
Depth
180mm
5.4 AquaSafe Alarm
Model
AquaSafe Alarm
Height
122mm
Width
124mm
Depth
85mm
4.4 AquaSafe Alarm
The system conforms to:
• The Low Voltage Directive, EN61010:2010
• The EMC Directive EN55014:2006, A1 and
EN55014-2:2015
Model
AquaSafe Alarm
Power Supply
230V AC 50hZ
Rated Power
<10VA
Internal Battery
6V, 1.3AH
Sound Alarm Level
85dB
Main Power Cable Length
1m
Weight
0.5kg
Material
ABS
Colour
Grey
Operating Temperature
-10°C to +40°C
4.5 Battery backup pump system
Model
BBPS
Power supply to panel
230V AC
Power supply to pump (via panel) 24V
Frequency
50Hz
Motor rating
Intermittent
Max. vertical output
6.5m
Max. horizontal output
45m
Max flow rate
180l/m
Max. liquid temp.
<40°C
Rated current
13A
Discharge size
1¼” / 32mm
Cable length
4m
Battery life
30min