WASTE WATER PUMPING SYSTEMS
Wykamol SumpFlo
™
29/44
Installation and operating guidelines
Technical advice: 0845 400 6666
www.wykamol.com
3.11.1 Control panel operation
The most important element of the battery backup system is the control panel as it controls and monitors and status of
the complete system.
The panel consists of both visual and audio indicators that are imperative for both the installer and end user to fully
understand.
Visual indicators
Indicator
Meaning
White Indicator (Supply On)
This indicates whether there is a mains supply connected to the
unit. Should the mains supply be removed (i.e. Power failure, blown
fuse) the light will go out.
Red Indicator (Fault)
This indicates that a fault is present within the Battery Backup
System. Fault could be as pump has tripped (blockage), mains
power is not present, or a battery fault. Please speak with your
supplier or call Edincare Pumps on 01442 211554
Green Indicator (Running)
This indicates that the backup pump is in operation.
Large Red Indicator c/w
Sounder (High Level Alarm)
This indicates that the water level within the pumping station is at
an excessive level. A fault maybe present with the pumping station.
Audio indicators
The battery backup system comes complete with an audio alarm to alert the user when there is a high level situation
within the chamber. Also located on the front of the panel is an alarm mute button to silence the alarm in a high level
situation.
Upon notification of this audio indicator, please check that the fault light is not illuminated on the control panel. It is also
advisable that you check the mains supply to the 240v pump/s is present.
Should any further help be required, please speak with your installer, supplier of Edincare Pumps 01442 211554.