Start
signal
Command
Length
Command
code
Channel /
Vendor option
Length /
Vendor
command
Payload
CS
0x02
0x1E
0x04
0x00
0x03
0x00
0x00
0x01
0x1A
Response:
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x80 0x00
0xDF
Test stopped successfully and received 0 packets.
7.6.2.2. Example: Receiver, channel 0
Start the reception test on channel 0 (2402MHz):
Start
signal
Command
Length
Command
code
Channel /
Vendor option
Length /
Vendor
command
Payload
CS
0x02
0x1E
0x04
0x00
0x01
0x00
0x00
0x00
0x19
Response:
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x00 0x00
0x5F
Test started successfully. In between we started the transmission test on a second module.
When we stop RX test now, we can count the received packets from the transmitting module.
Start
signal
Command
Length
Command
code
Channel /
Vendor option
Length /
Vendor
command
Payload
CS
0x02
0x1E
0x04
0x00
0x03
0x00
0x00
0x01
0x0B
Response:
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x8E 0x67
0xB6
Test stopped successfully and received 0x0E67 (3687) packets.
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
91