Würth RL 5-14
71
Troubleshooting
en
7
Troubleshooting
Alerts
Alert
Symptom
Possible causes and solutions
Low Battery LED flashes red, or
is on but not flashing.
The batteries are low. Replace the alkaline batteries
or recharge the Li-Ion battery pack. Refer to "5
Batteries".
Elevation (H.I.) Alert
The LEDs flash quickly with an
audio beep.
The RL 5-14 has been bumped or tripod was moved.
Turn off RL 5-14 to stop alert check the height of the
laser before beginning to work again. Allow RL 5-14
to re-level and check the height of the laser.
After two minutes in the alert condition, the unit will
shut off automatically.
Servo Limit Alert
All LEDs flash sequentially.
The RL 5-14 is tipped too far to reach a level position.
Re-level the RL 5-14 within the 5 degree self-levelling
range.
This alert will also be displayed any time the unit is
tipped more than 45° from level. After two minutes
in the alert condition, the unit will shut off automati-
cally.
Temperature Alert
All LEDs are on but not
flashing.
The RL 5-14 is in an environment where it cannot
operate without causing damage to the laser diode.
This could be a result of heat from direct sunlight.
Shade the RL 5-14 from the sun.
After two minutes in the alert condition, the unit will
shut off automatically.
5 Hz
+