![Würth ASS 14-1/4](http://html1.mh-extra.com/html/wurth-0/ass-14-1-4/ass-14-1-4_translation-of-the-original-operating-instructions_1001352016.webp)
16
Declaration of Conformity
We declare under our sole responsibility that the product
described under “Tool Specifications” is in conformity with the
following standards or standardization documents:
EN 60745 according to the provisions of the directives
2009/125/EC (Regulation 1194/2012), 2011/65/EU,
2004/108/EC, 2006/42/EC.
Technical file (2006/42/EC) at:
Adolf Würth GmbH & Co.KG, PFW,
Reinhold-Würth-Straße 12-17
74653 Künzelsau, Germany
Künzelsau: 10.07.2013
Battery Charging
Note:
The battery is supplied partially charged. To ensure
full capacity of the battery, completely charge the battery in
the battery charger before using your power tool for the first
time.
The lithium ion battery can be charged at any time without
reducing its service life. Interrupting the charging procedure
does not damage the battery.
The lithium ion battery is protected against deep discharging
by the “Electronic Cell Protection (ECP)”. When the battery is
empty, the machine is switched off by means of a protective
circuit: The inserted tool no longer rotates.
Do not continue to press the On/Off switch
after the machine has been automatically
switched off.
The battery can be damaged.
The battery is equipped with a NTC temperature control
which allows charging only within a temperature range of
between 0 °C and 45 °C. A long battery service life is
achieved in this manner.
Observe the notes for disposal.
Removing the battery
The battery
5
is equipped with two locking levels that should
prevent the battery from falling out when pushing the battery
unlocking button
6
unintentionally. As long as the battery is
inserted in the power tool, it is held in position by means of a
spring.
To remove the battery
5
, press the unlocking button
6
and pull
out the battery toward the front.
Do not exert any force.
Changing the Tool (see figure A)
Before any work on the machine itself (e. g.
maintenance, tool change, etc.) as well as dur-
ing transport and storage, remove the battery
from the power tool.
There is danger of injury when
unintentionally actuating the On/Off switch.
Regularly clean the power tool’s air vents.
The
motor’s fan will draw the dust inside the housing and
excessive accumulation of powdered metal may cause
electrical hazards.
ASS 14-1/4":
Inserting
Pull the locking sleeve
2
forward, push the insert tool to the
stop into the tool holder
1
and release the locking sleeve
2
to
lock the insert tool.
Use only screwdriver bits with ball catch
11
(DIN 3126-
E6.3). Other screwdriver bits
13
can be used with a universal
bit holder with ball catch
12
.
Removing
Pull the locking sleeve
2
forward and remove the insert tool.
ASS 18-1/2":
When working with an application tool, pay
attention that the application tool is firmly
seated on the tool holder.
When the application
tool is not firmly connected with the tool holder, it can
come loose again and not be controlled.
Slide the application tool onto the square drive of the tool
holder
1
.
However based on the system, if the application tool appears
wobbly after connecting securely on the tool holder
1
; this has
no influence on the function/safety.
T. Klenk
General Manager
A. Kräutle
General Manager