20
Frequency
▸
Set the selector switch
[9]
measuring range to
“
HZ/%
“.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the measuring leads to the circuit being
tested.
3
The measurement result is output at the display
[1]
.
Frequency
Measuring
range
Resolution
Accuracy
5 Hz
0.001 Hz
± 1.0 % + 4 d
50 Hz
0.01 Hz
500 Hz
0.1 Hz
5 kHz
1 Hz
50 kHZ
10 Hz
500 kHz
100 Hz
1 MHz
1 MHz
Sensitivity: 5 V
RMS
Max. input voltage: 120 V
RMS
Engine speed
▸
Set the selector switch
[9]
measuring range to “
“.
▸
Set the number of cylinders using the cylinder-
selection (CYL) button
[4]
.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the black measuring lead to the vehicle
ground.
▸
Connect the red measuring lead to the negative
terminal of the ignition coil.
3
The measurement result multiplied by 10 is
displayed.
Engine speed
Cylinder
Resolution
Accuracy
4 CYL
1 rpm
± 3.0 % + 5 digits
5 CYL
6 CYL
8 CYL
Sensitivity: 5 V
RMS
Max. input voltage: 120 V
RMS
Dwell angle (ignition point)
▸
Set the selector switch
[9]
measuring range to
“
Dwel
“.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the black measuring lead to the vehicle
ground.
▸
Connect the red measuring lead to the negative
terminal of the ignition coil.
Dwell angle
Cylinder Measuring
range
Resolution Accuracy
4 CYL
0–90
0.1
± 3.0 % + 5 d
5 CYL
0–72
6 CYL
0–60
8 CYL
0–45
Duty cycle
▸
Set the selector switch
[9]
measuring range to
“
HZ/%
“.
▸
Press the HZ/% button
[12]
to set to “%”.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the measuring leads to the circuit being
tested.
3
The measurement result is output at the display
[1]
.
Duty cycle
Measuring
range
Resolution
Accuracy
0–100 %
0.1 %
± 3.0 % + 5 d
Sensitivity: 5 V
RMS
Max. input voltage: 120 V
RMS
Capacitance measurement
▸
Set the selector switch
[9]
measuring range to “
F
“.
▸
Press zero balance (REL)
[2]
to zero.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the measuring leads to the circuit being
tested.
3
The measurement result is output at the display
[1]
.
Max. input voltage: 36 V
RMS
Summary of Contents for 0715 53 440
Page 3: ...1 2 3 4 5 6 7 9 8 12 11 10 I 3...
Page 4: ...4...
Page 104: ...104 GR W rth 3 1...
Page 105: ...105 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Page 176: ...176 BG W rth 3 1...
Page 177: ...177 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Page 212: ...212 RU W rth 3 1...
Page 213: ...213 50 120 30 50 120 W rth...
Page 239: ......