11
Components
Overview (fig. I)
1
Handle
2
LCD
3
Infrared sensor
4
Actuator (measurement button)
5
Battery cover
Indicator
6
Temperature values for MAX
7
Symbol for MAX
8
Currently measured value
9
Display of measured value
10
Data hold
11
Symbol laser on/off
12
Symbol lock
13
High/low alarm symbols (HAL; LOW)
14
Symbols for °C / °F
15
Low battery symbol
16
Symbol and value for emissivity
Keys
17
Down key (lighting (on/off))
18
Mode key (menu loop)
19
Up key (laser on/off)
Function overview
•
Precise non-contact measurements
• The excellent optical system allows measure
-
ments even from long distances
•
Wide temperature measurement range
•
Double laser pointer
•
MAX-HOLD-LOCK function
• Adjustable emissivity
•
Optical and acoustical alarm if the tempera-
ture falls below the freely adjustable values or
if it exceeds them
•
Backlight
• Possibility to select °C/°F
Technical specifications
Item
0715 53 110
Measuring range
-50 °C - 650 °C
(-58 °F - 1202 °F)
Optical resolution D:S
12:1
Display resolution
0.1 °C
Precision
(ambient temperature from 23°C - 25°C)
-50 °C ~ 20 °C
± 2.5 °C
20 °C ~ 300 °C
± 1.0 % ± 1.0 °C
300 °C ~ 650 °C
± 1.5 %
Reproducibility
-50 °C ~ 20 °C
± 1.3 °C
20 °C ~ 650 °C
± 0.5 °C
Response time
150 ms
Spectral responsitivity
8 ~ 14 μm
Operating temperature
0 - 50 °C
Storage temperature
-10 - 60 °C
Laser
Class II
Emissivity
adjustable from 0.10
to 1.0
Power supply
1 x 9 V battery
Relative humidity
10 % ~ 90 % RH (operation)
< 80 % RH (storage)