background image

W-LINK-CAN 

 

Product information 

Page 2 of 4                     Subject to technical changes 

 

W-LINK-CAN_V1.70_PI_2018-08_EN 

Writing conventions

 

Symbol 

Meaning 

 

CAUTION!

 

Avoid the described hazard: otherwise 

minor

 or 

medium

 physical injury or 

damage to property will result. 

 

WARNING!

 

Avoid the described hazard: otherwise there is danger from 

electric voltage

 that 

could lead to death or 

serious

 physical injury. 

For your safety 

For safe operation and to avoid personal injury and equipment damage through operating error, 
always read these instructions, become familiar with the device, and follow all safety instructions on 
the product and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG 
Elektronische Systeme. Keep these instructions ready to hand for quick reference and pass them on 
with the device if the product is sold. 
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of improper use or use for 
other than the intended purpose. 

Target group 

These instructions are intended for service technicians. 

Intended use 

The W-LINK-CAN receiver unit receives temperatures from W-LINKpro 
wireless product temperature sensors for documenting and monitoring and 
provides them to other devices via the CAN bus.

 

 

 

 
WARNING! 
Danger to life from electric shock and/or fire! 

 

Switch off the power to the entire plant when installing, wiring or removing! Otherwise a 
mains voltage and/or external voltage may still be present even if the control voltage is 
switched off! 

 

The wiring of the device should be carried out only by a qualified electrician! 

 

Use only the correct tools for all work! 

 

Check all wiring after connection! 

 

Take note of the maximum loads on all connections! 

 

Never expose the device to moisture, for example due to condensation or cleaning 
agents! 

 

Take the device out of operation if it is faulty or damaged and is therefore compromising 
safe operation! 

 

Do not repair the device yourself! If required, send it in for repair with an exact 
description of the fault! 

 

 

CAUTION! 

 

Electromagnetic interference can cause faults! 

 

Use only shielded data lines and place them far away from power lines! 

 

Software version and validity of the documentation 

Software version  Functional upgrade 

Page 

V1.5 

2009-05  Basis of documentation 

 

 

2011-04  Reception antenna folds to positioning angles 0°, 45° and 90°. 

V1.70 

2017-01  Front view, safety instructions, installation, technical data modified 

1-4 

 

2018-08  Documentation updates 

 

 
This document automatically ceases to be valid if a new technical description is issued. 

Manufacturer: 

Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid 

For further information, see our website at 

www.wurm.de

 

 

 

 

 

 