3.5.4 Connecting IQ sensors
Materials required
1 x SACIQ connection cable (see chapter 12 A
)
1 x cable gland with seal
The module end of the connection cable already has the sheath
removed in the factory and all the wires are fitted with wire end sleeves.
Tools
Phillips screw driver
Small screw driver.
Differentiating IQ sensors
of the same type in the
system
For the simpler correlation of measured value and measurement loca
-
tion, the system provides the option of giving each IQ sensor a user-
defined name (see section 5.4.1). This name appears on the measured
value display.
When the IQ sensor is delivered, the name is identical with the serial
number. Therefore, after the initial commissioning, IQ sensors of the
same type can only be differentiated by the serial number that appears
on the measured value display. In order to prevent confusing the
IQ sensors when assigning the name, you can proceed according to
one of the two methods:
Note the serial number of the IQ sensor at the respective measure
-
ment location before installation. Then, install all IQ sensors. After
the commissioning, open the list of sensors on the controller. Then
assign a suitable sensor name using the sensor type and the noted
serial number.
Disconnect the IQ sensors of the same type from the connection
cables before commissioning the system. Then, put the system into
operation. After the commissioning, connect the IQ sensors individ
-
ually to the SACIQ connection cable. To do so, proceed step-by-
step sensor for sensor. After each newly connected IQ sensor,
select the
Edit list of sensors
menu on the terminal and assign a suit
-
able sensor name to the sensor.
Connecting the SACIQ
cable to the MIQ module
The connection of the SACIQ cable to the terminal strip of an
MIQ module is described in section 3.5.3 (see C
Note
The SACIQ sensor connection cable may only be connected to the
SENSORNET connections. No wire of the cable may be connected
with an external electrical potential. Otherwise, malfunctions could oc
-
The list of sensors and the assignment of sensor names is
described in section 5.4.1 on page 5-3.
Summary of Contents for IQ SENSOR NET System 2020 XT
Page 2: ...Copyright 2016 Xylem Analytics Germany GmbH Printed in Germany...
Page 8: ...Contents System 2020 XT CONNECT 0 6 ba75970e01 10 2012...
Page 24: ...Overview System 2020 XT CONNECT 1 16 ba75970e01 10 2012...
Page 28: ...Safety System 2020 XT CONNECT 2 4 ba75970e01 10 2012...
Page 123: ...System 2020 XT CONNECT Settings setup 5 11 ba75970e01 10 2012 Fig 5 10 Edit list of sensors...
Page 138: ...Settings setup System 2020 XT CONNECT 5 26 ba75970e01 10 2012...
Page 152: ...Network connection System 2020 XT CONNECT 6 14 ba75970e01 10 2012...
Page 178: ...PROFIBUS connection option System 2020 XT CONNECT 8 12 ba75970e01 10 2012...
Page 180: ...Maintenance and cleaning System 2020 XT CONNECT 9 2 ba75970e01 10 2012...
Page 194: ...What to do if System 2020 XT CONNECT 10 14 ba75970e01 10 2012...
Page 204: ...Accessories and options System 2020 XT CONNECT 12 2 ba75970e01 10 2012...
Page 212: ...Lists IQ SENSOR NET System 2020 XT CONNECT 13 8 ba75970e01 10 2012...
Page 215: ......