background image

Quality ensurance

Wilhelmsen Ships Service (WSS) recommend a 
monthly visual inspection and a yearly inspection 
of all suits by using the portable test kit to 
observe any defects or quantity or functional 
noncompliance. These best practices will ensure 
product quality is maintained and product is fit for 
use when needed in case of emergency.

Visual inspection

1.

   Check the condition of the bag for damage, 

dirt or unreadable instructions, check if the 
description outside complies with the size and 
suit type inside.

2.

   Take out the suit from the bag and place it 

on a flat clean table, make sure the suit is dry 
both from inside and outside. 

3.

   Check for missing parts such as whistle, snap 

hook, buddy line, wax for zipper, emergency 
light (only for pillow type 7P version), and 
replace if necessary only with original parts 
from manufacturer. Visually check the suit 
inside and outside for damages, damages as 
punctures, tears, ripped neoprene – if found 
please return this for service to your local WSS 
service station at your nearest opportunity

4.

   Check the watertight metal zipper for damage. 

Remove all dirt or debris from the zipper. Use 
the wax stick provided to lubricate the zipper 
for smooth operation 

5.

   Check the connection joints of the buoyancy 

pillow to the suit and also leg fastener straps, 
if founds damaged please return this for 
service to your local WSS service station at 
your nearest opportunity

Summary of Contents for UNITOR 7P

Page 1: ...OPTIMISING PERFORMANCE USER MANUAL UNITOR IMMERSION SUIT 7P...

Page 2: ...is dry both from inside and outside 3 Check for missing parts such as whistle snap hook buddy line wax for zipper emergency light only for pillow type 7P version and replace if necessary only with or...

Page 3: ...check for leakages Product structure as follow Plastic box Stable and pressing boards Charging hose ball valve assembly 0 4KPa pressure gauge assembly Repair kit 1pc glue 1pc brush 1pc wax 1pc operat...

Page 4: ...o the head and make sure the quick connector and threaded port are free to access from the face 4 Insert the pressure gauge assembly and charging hose ball valve assembly into the quick connector of p...

Page 5: ...mb push the connector inside first then you can pull them out from the pressing board Release the air pressure slowly in the suit and then hang the suit to dry 8 Wash all tested suits according to the...

Page 6: ...e leak area of the internal of immersion suit over 25mm extended from the leak point in all directions then cut a suitable patch with 5mm less than the area spread on the suit in all directions and sp...

Page 7: ...ing dry it naturally but not in heavy sunshine or in the proximity of heaters or UV supplying machines Hang it for drying on a wide stable garment hanger until it is really dry 9 Lubricate the front a...

Page 8: ...nd then switching it off after 10 seconds Press the manual test button both for switching ON and OFF the light 3 Insert the securing clip of the emergency light into the emergency light securing webbi...

Page 9: ...r clothing Insert both arms first Don lower body part Put on the hood fully close the zip and squat to remove excess air Tighten the strap around the ankle Close face flap and prepare to jump in water...

Page 10: ...stal address Visiting address P O Box 33 Strandveien 20 N 1324 Lysaker N 1366 Lysaker Norway Norway T 47 67584550 F 47 67584570 E wss info wilhelmsen com wilhelmsen com shipsservice Part of Wilhelmsen...

Reviews: