background image

1. Oil reservoir: To store hydraulic oil, make sure the reservoir enough oil to keep the pump work

normally.

2.The adjusting pressure regulator: Adjust this valve for setting the working pressure of power pack

(the)max working pressure has been locked before sales, please do not change the locked pressure 

at any time.

3. Pressure gauge: it’s effects 0-1000Bar, showing the working pressure of the power pack.

4. Frame for protecting: it is fixed on motor for carrying conveniently.

5. Motor: provide power.

6. Radiator: to exclude the heat, ensure the operating time and life of the pump.

7. Oil level measurer: it can help us know the oil level, when the oil less than the1/3 of total, please

Fill the especial oil for hydraulic tools of WREN.

8. Release oil port: G1/4.

9. Control system: the integrated electric equipment of the pump.

10. Cover plate for oil tank: seal the oil tank and install the parts of power pack.

11. Solenoid valve: Its function is output oil when the pressure is very high, control the flow when

return oil, and soon. It can be set up the maximum pressure and protect system to work normally at the 

pressure set up. The threads of oil output port is NPT1/4”.

12. Quick coupler : it’s function is output oil when the pressure is very high, control the flow when

return oil , and so on, it can be set up the maximum pressure and protect system to work normally at 

the pressure set up, the threads of oil output port is NPT 1/4” 

13. Valve block: control oil driving in and out; make sure the hydraulic system can be worked normally

under the pressure to be set up. 

14. Oil filling port: To be used for filling and replacing oil.

2

, 46# or other same grade

72

Bar

7

Summary of Contents for KLW4010 EX

Page 1: ...KLW4010 EX Operation And Maintenance Manual Of KLW4010 Explosion proof Hydraulic Pump Explosion proof...

Page 2: ...ll be out of our warranty Range 10 Please do not fill the pump reservoir with too much oil otherwise the pressure of the reservoir will increase and the oil will spill over so the reservoir will be br...

Page 3: ...WREN 8 Release oil port G1 4 9 Control system the integrated electric equipment of the pump 10 Cover plate for oil tank seal the oil tank and install the parts of power pack 11 Solenoid valve Its func...

Page 4: ...AND DESCRI PT I ON OF PARTS Item Description Item Description 1 Electrical control system 5 Pump Head Assembly 2 Motor 6 Oil pipe Assembly 3 Pressure gauge 7 Oil return pipe Assembly 4 Oil tank Assem...

Page 5: ...8 6 1 1 117 And cover on the dust cap 380 4 2 2 690 520 476cm with 1 EX KL 1...

Page 6: ...ntroller and adjust the pressure unit the working Plessure reach to what you need and then loosen the retract button on the controller 3 Operation 3 1 Please press down the retract button on the contr...

Page 7: ...1 Check Valve Assembly 1 4 3 O Ring 4 11 1 Check Valve 1 4 4 Retaining Ring 2 11 2 Retaining Ring 1 4 5 O Ring 2 11 3 O Ring 1 4 6 O Ring 2 11 4 O Ring 1 5 Steel Ball 5 12 Low Pressure Valve Assembly...

Page 8: ...valve 2 7 1 Check Valve 1 set 7 2 Retaining ring 1 set 7 3 O ring 1 set 7 4 O ring 1 set 7 5 Retaining ring 1 set 8 Release valve 2 1 8 1 Relief Valve 1 set 8 2 Retaining ring 1 set 8 3 O ring 1 set...

Page 9: ...system Repeat operating the system with no load for several times to eliminate air The leaking valve may be frayed Replace it please High pressure leaking valve may not be tightened Tighten it please...

Page 10: ...HYDRAULIC PRINCIPLE 700Bar 9 700Bar 1000Bar...

Page 11: ...om 2 Explosion proof button box BZC8050 Warom 3 Explosion proof plug device BCZ85 380V 16A Warom 4 Explosion proof line tube BNG 6M Warom 5 Explosion proof line tube BNG 5M Warom 6 Explosion proof lin...

Page 12: ...draulic pump noise value 70db 2 Hydraulic pump transport information 1 Handle with care 2 The shipment should be vertical upward as shown in the figure 9 1 FIG 9 1 3 Product handling generally using p...

Page 13: ...ment WARNING Do not exceed equipement ratings the pimps are designed for a max pressure of 10 000Psi 700Bar Do not connect a jack or cylinder to pump with a higher pressure rating Never set the relief...