background image

1.When using, do not permit any person stand at the oil output in order to avoid personal injury and

equipment damage. Please put the pump far away from the fire.

2.Make sure that the hose and quick coupler be connected before building up the pressure in order to

avoid hydraulic fluid spurting out to cause personal injury.

3.The maximum operating pressure of this pump is 700Bar(10,000Psi),WREN has set up the pressure to

700Bar before selling this pump. Please do not adjust to a pressure higher than the maximum pressure 

whichWREN has not set.

4.If this pump is used for operating other equipments, make sure the maximum operating pressure of the

equipments will be less than 700Bar. Please adjust the pressure to which the equipment need, or else the 

equipment would be damaged.(Referrence content 5)

5.Make sure the power of the pump is shut off before repairing it.

6.Please shut off the switch before starting power; if the switch is on, the pressure may increase.

7.Make sure the equipment be connected with ground to avoid electric shock.

8.Do not start the pump without oil in tank.

9.Please do not change any part of the pump; if it must be changed, please inform WREN or Wren's agent

for help. Without allowance of WREN or its agent, any refit of it will be out of our warranty Range.

10.Please do not fill the pump reservoir with too much oil, otherwise, the pressure of the reservoir will

increase and the oil will spill over, so the reservoir will be broken and the environment will be polluted.

11.When the pump works,the pressure may be increased with the returning oil.If the oil filler cop is opened

at the moment, this may cause the injury.

12.Make sure the quick coupler is tightened; if the quick coupler is not tightened enough, the equipment

will not work normally; if it is a synchronic system, the problem may cause one or several pieces of 

equipment out of order and the quick coupler may be broken and it may cause personal injury or equipment 

damage.

13.Make sure to reep the pump in cleaning.

14.Please stand away from the position where the hydraulic oil may be spurt out; hydraulic

oil may penetrate your hand and hurt you.

15.If the hydraulic oil splashed in your eyes, please immediately wash your eyes about 15

minutes with clean water, then you must go to hospital for help right now.

PICTURE 2

16.Please do not touch the pressurized hose; if the hydraulic oil splashed out, it will cause serious

injury.

17.Hydraulic hose is easily spoiled fitting; you inspect the hose with eyes regularly and find no problems,

but the inner side may have crack and small hole; WREN suggests you should change the hose regularly 

for smoothing use.When using,try to avoid bending the hose in sudden.

11

disposed

Summary of Contents for KLW4010 EX

Page 1: ...KLW4010 EX Operation And Maintenance Manual Of KLW4010 Explosion proof Hydraulic Pump Explosion proof...

Page 2: ...ll be out of our warranty Range 10 Please do not fill the pump reservoir with too much oil otherwise the pressure of the reservoir will increase and the oil will spill over so the reservoir will be br...

Page 3: ...WREN 8 Release oil port G1 4 9 Control system the integrated electric equipment of the pump 10 Cover plate for oil tank seal the oil tank and install the parts of power pack 11 Solenoid valve Its func...

Page 4: ...AND DESCRI PT I ON OF PARTS Item Description Item Description 1 Electrical control system 5 Pump Head Assembly 2 Motor 6 Oil pipe Assembly 3 Pressure gauge 7 Oil return pipe Assembly 4 Oil tank Assem...

Page 5: ...8 6 1 1 117 And cover on the dust cap 380 4 2 2 690 520 476cm with 1 EX KL 1...

Page 6: ...ntroller and adjust the pressure unit the working Plessure reach to what you need and then loosen the retract button on the controller 3 Operation 3 1 Please press down the retract button on the contr...

Page 7: ...1 Check Valve Assembly 1 4 3 O Ring 4 11 1 Check Valve 1 4 4 Retaining Ring 2 11 2 Retaining Ring 1 4 5 O Ring 2 11 3 O Ring 1 4 6 O Ring 2 11 4 O Ring 1 5 Steel Ball 5 12 Low Pressure Valve Assembly...

Page 8: ...valve 2 7 1 Check Valve 1 set 7 2 Retaining ring 1 set 7 3 O ring 1 set 7 4 O ring 1 set 7 5 Retaining ring 1 set 8 Release valve 2 1 8 1 Relief Valve 1 set 8 2 Retaining ring 1 set 8 3 O ring 1 set...

Page 9: ...system Repeat operating the system with no load for several times to eliminate air The leaking valve may be frayed Replace it please High pressure leaking valve may not be tightened Tighten it please...

Page 10: ...HYDRAULIC PRINCIPLE 700Bar 9 700Bar 1000Bar...

Page 11: ...om 2 Explosion proof button box BZC8050 Warom 3 Explosion proof plug device BCZ85 380V 16A Warom 4 Explosion proof line tube BNG 6M Warom 5 Explosion proof line tube BNG 5M Warom 6 Explosion proof lin...

Page 12: ...draulic pump noise value 70db 2 Hydraulic pump transport information 1 Handle with care 2 The shipment should be vertical upward as shown in the figure 9 1 FIG 9 1 3 Product handling generally using p...

Page 13: ...ment WARNING Do not exceed equipement ratings the pimps are designed for a max pressure of 10 000Psi 700Bar Do not connect a jack or cylinder to pump with a higher pressure rating Never set the relief...

Reviews: