9.2. Connecting & Configuring Relay Out
9.2.1. Specifications
In order to operate the relay outputs of the DRS Digital Recording Solution
(all models)
normally, the
following conditions are required.
Output Ch.
4Ch. Relay differential outputs
Output type
Dry Contact
Spec.
Connecting type
Connect the trimmed wire to the screwless terminal block
24V DC, 1.25A, 30W
DC
125V DC, 0.24A, 30W
Rating
AC 125V
AC,
0.5A,
62.5VA
9.2.2. Connecting Relay Out
When connecting R1 ~ R4 refer to the following diagram. This diagram shows connection to a warning
light.