background image

PZM

IV

 & PZMT

IV

World Precision instruments

3

Parts Diagram for PZM

IV

 and PZMT

IV

Key

(1)

 eyepiece

(2)

 diopter Adjustment 

ring 

(3)

 magnification            

indicating ring

  Above the right-

hand knob (hidden 
in this photo) is a 
detent control to 
provide discreet 
zoom stops or 
continuous zooming.

(4)

 magnification            

Knob

(5)

 Body rotation 

clamp locking 
screw

(6)

 stage Plate

(7)

 Focusing                 

Knob

(8)

 track 

(9)

 Base

PZMT

IV

 only:

(10)

 ccd color Video 

camera (optional)

(11)

 c-mount ccd 

camera coupler 
(optional)

(12)

 Video/Photo Port

(13)

 light Path selector 

Bar 

— when 

out, light to the 
right eyepiece is 
switched to the 
photo port.

10

11

Fig. 1

1

2

3

8

9

7

4

5

6

12

13

Summary of Contents for PZMIV

Page 1: ...PZMIV PZMTIV Precision Zoom Stereo Microscopes INSTRUCTION MANUAL Serial No _____________________ 072105 World Precision Instruments www wpiinc com ...

Page 2: ...TIV System Diagram 4 Specifications 5 Operation 6 Maintenance 7 Appendix Boom Stand Assembly 8 Warranty 9 Copyright 2004 by World Precision Instruments Inc All rights reserved No part of this publication may be reproduced or translated into any language in any form without prior written permission of World Precision Instruments Inc ...

Page 3: ... optics provide image sharpness found only among the best of this class PZMIV uses modular parallel beam path design and a high quality optical system The advanced optical design with plan achromatic objectives provides sharp and distortion free image throughout the entire zoom range The ergonomic design makes it easy to use zooming is smooth and effortless controlled by a large spring loaded knob...

Page 4: ...nd 3 Mount the microscope head into the focus mount 4 Remove the protective cap on the bottom of the microscope head 5 Refer to the parts diagram on page 3 and follow the set up instructions below 6 Install the WFH 10x eyepiece pair 1 included The paired eyeguards can now be attached to the eyepieces 7 The exact working distance is found by adjusting the focusing knob 7 8 When the optional stands ...

Page 5: ...etent control to provide discreet zoom stops or continuous zooming 4 Magnification Knob 5 Body Rotation Clamp Locking Screw 6 Stage Plate 7 Focusing Knob 8 Track 9 Base PZMTIV only 10 CCD Color Video Camera optional 11 C Mount CCD Camera Coupler optional 12 Video Photo Port 13 Light Path Selector Bar when out light to the right eyepiece is switched to the photo port 10 11 Fig 1 1 2 3 8 9 7 4 5 6 1...

Page 6: ...02003 Objectives 0 32x 502016 0 5x 502017 0 63x 502018 1 0x 502019 Eyepieces 10x 502010 16x 502011 20x 502012 25x 502013 Digital camera with integrated lens filter thread of 28 37 or 43 mm Digital Camera Adapter Kit 501384 Video Camera COLCAM CCD Coupler 0 3x 500261 0 5x 500262 0 75x 500263 Ring Light Adapter 502015 Pixera VCS 10132 Track Stand 502002 Binocular Body 502000 Trinocular Body 502001 I...

Page 7: ...ves 10x Eyepiece 16x Eyepiece 20x Eyepiece 25x Eyepiece Objective Mag Field mm Video Field Mag Field mm Video Field Mag Field mm Video Field Mag Field mm Video Field Working Distance 0 32x 1 9x 16x 106 13 1 49 8 6 1 3 2x 25 6x 70 6 8 8 49 8 6 1 3 9x 32x 55 4 6 9 49 8 6 1 5x 40x 45 4 5 6 49 8 6 1 296 mm 0 5x 3 1x 25x 67 7 8 4 31 8 3 95 5x 40x 45 2 5 6 31 8 3 95 6 2x 50x 35 5 4 4 31 8 3 95 7 8x 62 8...

Page 8: ...y zoom out to lower magnification by adjusting magnification knob 4 while remaining in focus 4 Diopter Adjustment If image does go out of focus when zooming out zoom to the lowest setting and focus each eyepiece individually by adjusting the diopter adjustment ring 2 5 Video Photo Applications Slide the light path selector bar 13 to the PHOTO IN position in order to direct the light to the video p...

Page 9: ...t spray If stains deposit on exterior surfaces of the lenses clean them gently using a mild soap solution with a lint free cloth Industrial solvents should not be used since they may penetrate to the inside of the lens components and dissolve the lens cement When cleaning and lubricating the mechanical parts special attention must be taken not to stain the optical surfaces with grease The moveable...

Page 10: ...st 4 Insert Horizontal Bar into opening in cross block slot side facing up Two different types of focusing assemblies are available E arm 1 Remove E arm from protective packaging 2 Insert E arm into the end of the Horizontal Bar secure by tightening set screw 3 Tighten one or both hex screws 2 5 mm and 4 mm so the microscope head is tiltable but not free to swing Tips E arm can be inserted from th...

Page 11: ... or fitness for a particular purpose WPI shall not be liable for any damages whether direct indirect special or consequential arising from a failure of this product to operate in the manner desired by the user WPI shall not be liable for any damage to data or property that may be caused directly or indirectly by use of this product Claims and Returns Inspect all shipments upon receipt Missing cart...