4
World Precision Instruments
Unpacking
Upon receipt of this instrument, make a thorough inspection of the contents and
check for possible damage. Missing cartons or obvious damage to cartons should be
noted on the delivery receipt before signing. Concealed damage should be reported
at once to the carrier and an inspection requested. Please read the section entitled
“Claims and Returns” on page 31 of this manual. Please contact WPI Customer
Service if any parts are missing at 941.371.1003 or [email protected].
Returns:
Do not return any goods to WPI without obtaining prior approval (RMA
# required) and instructions from WPI’s Returns Department. Goods returned
(unauthorized) by collect freight may be refused. If a return shipment is necessary,
use the original container, if possible. If the original container is not available, use a
suitable substitute that is rigid and of adequate size. Wrap the instrument in paper or
plastic surrounded with at least 100mm (four inches) of shock absorbing material. For
further details, please read the section entitled “Claims and Returns” on page 31 of
this manual.
INSTRUMENT DESCRIPTION
Hardware Installation
1. Set the
MPS-4
perfusion stand on a stable platform.
2. Insert the stainless steel post into the base and tighten the screw.
3. Loosen the screw on the back of the valve console and fix it onto the post. Set
the distance between the valve console center point and top of the post to the
desired height.
4. Fasten the syringe holder onto the post.
5. Connect the valve console to the
MPS-4
instrument with the cable supplied.
6. Pull out of the plungers of the syringes and put the syringes into the syringe
holder.
7. Connect the 3-way stopcocks to the syringes.
8. Cut a 20cm long section of the color-coded polyurethane tubing. Split it to 8
individual tubes and put the luer fitting to one end. Connect the luer fitting to the
3-way stopcock.
9. Connect the other ends of the eight tubes to the inputs of the valve console.
10. Split one end of the long color-coded polyurethane tubing for about 15cm.
Connect the splited end to the valve output port on the valve console.
11. Carefully connect the other ends of the polyurethane tubing to the µ-manifold.
CAUTION
: In this step, the manifold should not be connected to the holding
rod. The female luer port may be damaged by the force applied to the manifold
when attaching the 8 ends of the tubing.