Perform the following test to determine whether or not a load surface is too porous or rough:
Lifter/Load Compatibility Test
1
1) Make sure the vacuum generating system is functioning correctly (see
page 27).
2) Thoroughly clean the load surface and the vacuum pads (see
3) Place the load in the upright position on a stable support.
4) Attach the vacuum pads to the load as previously directed.
5) After the vacuum level appears in the green range on the vacuum gauge, place the power
switch in the “off” position (
).
6)
Take precautions in case
load should fall during test.
Raise the load a minimal distance, to make sure it
is supported by the lifter.
7) Watch the vacuum gauge:
Starting from a
vacuum level of 16" Hg [-54 kPa], the lifter must maintain a vacuum level greater than
12" Hg [-41 kPa] for 5 minutes.
2
If not, lifting this load requires additional precautions
(eg, a load sling). Contact WPG for more information.
8) Lower the load
after
5 minutes or
before
the vacuum level diminishes to 12" Hg [-41 kPa].
1..... The
“Pad-to-Load Friction Coefficient”
(see page 29) can affect the outcome of this test.
2..... Under CE requirements, the lifter must maintain a vacuum level
greater than 8" [-27 kPa]
.
INSPECTIONS AND TESTS
Summary of Contents for MRPTHD1211LAC
Page 2: ...MRPTHD AC 35066 Rev 1 0 2 21 2...
Page 7: ...Rev 1 0 2 21 MRPTHD AC 35066 5 Note Standard MRPTHD2011LAC is shown SPECIFICATIONS...
Page 35: ...MRPTHD AC 35066 Rev 1 0 2 21 34...
Page 36: ...Rev 1 0 2 21 MRPTHD AC 35066 35...
Page 37: ...MRPTHD AC 35066 Rev 1 0 2 21 36...
Page 38: ...Rev 1 0 2 21 MRPTHD AC 35066 37...
Page 39: ...MRPTHD AC 35066 Rev 1 0 2 21 38...
Page 40: ...Rev 1 0 2 21 MRPTHD AC 35066 39...
Page 41: ...MRPTHD AC 35066 Rev 1 0 2 21 40...
Page 42: ......