If Your Thermo-sealer does not work correctly, carry out the following checks before contacting the Technical Service:
6.Troubleshooting
Envelope cutting is difficult.
SUGGESTED SOLUTION
12
The LED is solid red and the
machine is emitting an
acoustic signal
NOTE
SHOULD THE PROBLEM PERSIST, PLEASE CONTACT OUR TECHNICAL SERVICE NETWORK
REPORTING THE THERMOSEALER MODEL AND ITS SERIAL NUMBER.
THESE DATA CAN BE FOUND ON THE FACTORY PLATE PLACES ON THE UNIT REAR.
PROBLEM
POSSIBLE CAUSE
The thermo-sealer does
not switch on.
The plug of the power supply cable is not inserted
inthe outlet.
Properly put in the plug.
Lack of power at the power supply outlet.
The magneto thermal switch and/or differential switch
of the installation are OFF.
Mains fuses broken
Check the possible cause of power
failure and try to solve it.
Replace the fuses
(see Appendix C - Maintenance)
Put the switches to ON position.
The LED does not fl ash when
the thermo-sealing machine
is switched on
Heating resistance broken.
Contact the Technical Support Service
Bag sealing is performed but
the LED remains a fixed green
(instead of red) and no
acoustic signals are heard.
Fault of the end-of-run microswitch.
Insufficient pressure in the sealing area.
Silicon rubber profile damaged.
Resistance does not reach the operating temperature
The Led does not work.
Fault in the electronic card.
Contact the Technical Support Service
Consumed blades.
Contact the Technical Support Service
Contact the Technical Support Service
Operator warning signal
SIGNAL
ACTION
CAUSE
The LED is fl ashing green
The machine is warming up
Wait until the machine warms up.
The LED is steady green
The machine is ready for use
The LED is fast fl ashing green The sealing handle has been lowered and the
machine is in use
Wait for the acoustic signal, lift the lever
and remove the bag
The green LED emits a brief
flash every 5 seconds
The machine is in a paused status after a period
of inactivity of 30 minutes.
Lower and lift back up the
to rest
normal operation.
handle
The red and green LEDs
flash at the same time
The machine signals the presence of a heating
system problem.
Switch off and retry machine use. If the
signal recurs, contact Technical Support.
The sealing operation has been completed
The machine is on with the sealing lever down
The sealing
was lowered before reaching
the proper operating temperature
handle
Lift the handle
Lift the
and remove the bag
handle