12
[ELECTRICAL STARTER MODEL]
•
Insert the key inside the switch key and turn it to the ‘‘ I ’’ position. Then turn it right (START) in order
to start the engine. Fig.
7
2
•
When the engine started, turn the choke knob slowly to make the engine run and keep it to the full
normal position. Do no open it quickly when the engine is cold or the outside temperature is cold,
because the engine might stop. Let the engine warm for few minutes without load. Fig.
7
3
5.2. USING ELECTRIC POWER
AC APPLICATION
This generator is thoroughly tested and adjusted in the factory. If the generator does not produce the
specified voltage, consult your nearest Worms Entreprises dealer or service shop.
Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.
Insert the plug(s) of the electrical appliance(s) into the receptacle. Fig.
8
Be sure to ground the generator if the connected electrical device is grounded.
Failure to ground unit could lead to electrical shock.
•
Check the amperage of the receptacles, and be sure not to take a current exceeding the specified amperage.
•
Be sure that the total wattage of all appliances does not exceed the rated output of the generator.
Do not put foreign objects into the plug receptacle.
Fig.
9
NOTE
When the circuit breaker or no-fuse breaker turns off during operation, the generator is overloaded or
the appliance is defective. Stop the generator immediately, check the appliance and/or generator for
overloading or detect and have repaired as necessary by Worms Entreprises dealer or service shop.