48
AccEss 2200 XL
Bulb / Halogen / Heating
2200 W
Neons - Low consumption Bulb
1100 W
gringer
1300 W
Compressor
700 W
Electric Engine Without Load
1500 W - 2 HP
voLtAgE drop iN ELEctric EXtENsioN cords
When a long electric extension cord is used to connect an appliance or tool to the generator, a certain
amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage
available for the appliance or tool.
The chart below has been prepared to illustrate the approximate voltage loss when an extension cord
of 300 feet (approx. 100 meters) is used to connect an appliance or tool to the generator.
Nominal Cross
No.
de
calibre A.W
.g
.
Allowable Current
Nb.
de
brins
/ ø
d’1
brun
Résistance
Ampérage (A)
mm
2
No.
A No./mm /100m 1 A 3 A 5 A 8 A 10 A 12 A 15 A
0,75
18
7 30/0.18 2,477 2,5V 8V 12V
-
-
-
-
Voltage
drop
1,27
16
12 30/0.18 1,486 1,5V 5V 7,5V 12V 15V 18V
-
2,0
14
17 37/0.26 0,952 1V
3V
5V
8V 10V 12V 15V
3,5 12 à 10 23 45/0.32 0,517
-
1,5V 2,5V 4V
5V 6,5V 7,5V
3,5 10 à 8 35 70/0.32 0,332
-
1V
2V 2,5V 3,5V 4V
5V
12. MAiNtENANcE schEdULE
daily (8 h)
•
Check all components according to ‘’PRE-OPERATINg CHECKS’’.
•
Check and refill gasoline and engine oil.
After 20 h or for the
1st month
•
Change oil more often if used in dusty or dirty environment.
Every 50 h
•
Wash air cleaner foam element more often if used in dirty or dusty
environments.
•
Check the condition of the paper element. Do not wash the paper element.
Every 100 h
•
Change oil more often if used in dusty or dirty environment.
•
Check the spark plug and clean it if necessary.
•
Clean the fuel strainer and the fuel sediment cup.