background image

23 

AFTER SALES SUPPORT

www.einhell.co.uk

t

 0044 151 649 1500

      0044 1890 946 244

IRE

WAC 3050/1

03/2015

3HP 50L AIR COMPRESSOR

Your details:

Name

 

Address

 

E-Mail 

Date of purchase* 

*We recommend you keep the receipt with this warranty card

Location of purchase 

Description of malfunction:

Return your completed warranty card to:

Einhell UK Limited

Unit 9, Stadium Court,

Wirral International Business Park,

Plantation Road,

Bromborough,

Wirral, CH62 3QG

[email protected]

[email protected]

AFTER SALES SUPPORT

www.einhell.co.uk

0044 151 649 1500
0044 1890 946 244

IRE

MODEL: WAC 3050/1   91977   03/2015

YEAR WARRANTY

IMPORTANT! KEEP THIS FORM SAFE: 

 Only complete and return this form to the 

address below in the unlikely event of a warranty claim, if you are requested by the 
manufacturer to return the item for replacement. Then please complete this form 
and send it together with your receipt (proof of purchase) to the address below.

WAC_3050_1_EX_GB_SPK7.indb   23

16.10.14   11:34

Summary of Contents for WAC 3050/1

Page 1: ...90 946 244 IRE MODEL WAC 3050 1 91977 03 2015 Now you have purchased a Workzone product you can rest assured in the knowledge that as well as your 3 year parts and labour warranty you have the added p...

Page 2: ...sive manufacturer s 3 year warranty and an outstanding after sales service through our dedicated Helpline We hope you will enjoy using your purchase for many years to come If you require technical sup...

Page 3: ...1 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 Contents 04 Safety information 09 Parts description and assembly 15 Instructions 20 Frequently asked questions 21 Technical data 22 Warranty Certifi...

Page 4: ...quipment is allowed to be used only for its intended purpose Any other use is deemed to be a case of misuse The user operator and not the manufacturer will be liable for any damage or injuries of any...

Page 5: ...es or those with no experience and or knowledge unless they are supervised by a person who is responsible for their safety or they have received instructions from such a person in to how to use the eq...

Page 6: ...e On Off switch is in the Off position when connecting to the power supply 12 Extension cable outdoors Use an extension cable outdoors only if is approved for outdoor duty and is marked accordingly 13...

Page 7: ...t any maintenance or cleaning work on the compressor Do not spray the compressor with water or inflammable liquids No inflammable objects must be situated near the compressor Please do not store or us...

Page 8: ...e always used for compressed air and that they are suitable for the maximum operating pressure of the compressor Do not attempt to repair damaged lines Mains connection The motor is equipped with an o...

Page 9: ...essure gauge tank 9 Safety valve 10 Discharge line 11 Air filter 12 Oil sealing plug 13 Oil drainage screw window 14 Drainage cock 15 Overload switch 16 Transport handle Package contents 1 Compressor...

Page 10: ...www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 20 20 17 17 27 19 27 18 18 19 20 21 F 22 23 24 25 26 26 25 24 22 23 G Max 100 B ON ON OFF C D 14 E WAC_3050_1_EX_GB_SPK7...

Page 11: ...signation Position 401043001001 Oil filler plug 17 401043001002 Air filter 37 401043001003 Drain cock 67 401043001004 Safety valve 73 401043001005 Universal quick release coupling 74 401043001006 Pres...

Page 12: ...12 AFTER SALES SUPPORT www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 WAC_3050_1_EX_GB_SPK7 indb 12 16 10 14 11 34...

Page 13: ...he equipment and packaging material are not toys Do not let children play with plastic bags plastic sheets and small parts There is a risk of choking and suffocating Assembly Once the compressor has b...

Page 14: ...sure that the device cannot fall down To ensure adequate ventilation and effective cooling the distance between compressor and walls must be at least 100 cm Transporting the compressor Switch off the...

Page 15: ...bar 29 psi Example The compressor stops working as soon as it reaches 8 bar 116 psi max operating pressure and restarts automatically when the pressure in the tank falls to 6 bar 87 psi After connecti...

Page 16: ...ing pressure as most compressed air tools have low pressure requirements The correct operat ing pressure must be set on compressors fitted with a pressure reduction device The operating pressure can b...

Page 17: ...ver use solvents such as petrol alcohol ammonia water etc These sol vents can damage the plastic parts Cleaning replacing air filter It is recommended to dismantle the intake filter every 50 hours of...

Page 18: ...seal Pour the oil through the oil filler opening in the crankcase and then reinsert the sealing plug 12 check the oil level in the pump system every week and replenish with oil as and when required Us...

Page 19: ...nvironment The machine is supplied in robust packaging in order to prevent trans port damage The packaging largely consists of recyclable materials Please therefore take the opportunity to recycle the...

Page 20: ...voltage shown on the rating plate Has an extension cable with the wrong cross section or length been used Is the work area too cold below 0 C Is there oil in the crankcase to provide adequate lubricat...

Page 21: ...compressor is set up The product meets the requirements of EN 61000 3 11 and is subject to special connection conditions This means that use of the product at any freely selectable connection point i...

Page 22: ...ty period This also applies if an on site service is used The warranty is valid for a period of three years starting from the purchase date Keep your sales receipt in a safe place as it is your proof...

Page 23: ...iness Park Plantation Road Bromborough Wirral CH62 3QG sales einhell co uk technical einhell co uk AFTER SALES SUPPORT www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE MODEL WAC 3050 1 9197...

Page 24: ...ni ej artyku u z nast puj cymi normami na podstawie dyrektywy WE BG LV paskaidro du atbilst bu ES direkt vai un standartiem LT apib dina atitikim EU reikalavimams ir prek s normoms RO declar urm toare...

Page 25: ...25 AFTER SALES SUPPORT www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 WAC_3050_1_EX_GB_SPK7 indb 25 16 10 14 11 34...

Page 26: ...26 AFTER SALES SUPPORT www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 WAC_3050_1_EX_GB_SPK7 indb 26 16 10 14 11 34...

Page 27: ...27 AFTER SALES SUPPORT www einhell co uk t 0044 151 649 1500 0044 1890 946 244 IRE WAC 3050 1 03 2015 WAC_3050_1_EX_GB_SPK7 indb 27 16 10 14 11 34...

Page 28: ...EH 09 2014 01 WAC_3050_1_EX_GB_SPK7 indb 28 16 10 14 11 34...

Reviews: