13

 WARNING: 
  •   To prevent serious injury from accidental operation, turn the 

power switch of the vacuum off and unplug the appliance from its 

electrical outlet before performing any procedure in this section. 

 

•   Before you connect the vacuum to a mains supply, make sure that 

the data on the rating / technical label is identical to the mains data. 

 

•    The Wet and Dry Vacuum should only be connected to a mains 

power supply socket; an RCD (Residual Current Device) is 

recommended.

The Wet and Dry Vacuum requires some assembly prior to use. This includes 

assembly of the wheels, and dependent upon the use of the product, the 

flexible hose, tubes, filters, and accessories.  The following detail covers the 

assembly required for each function of the Wet and Dry Vacuum.

Assembly of the wheels

1.   Remove the appliance head (2) from the tank (10) by unlocking the  

2 x side locking handles (6) pulling them outwards, then upwards (Fig A). 

Then turn the tank (10) upside down.

2.   Fit the 4 x castor wheels (13) by inserting the mounting pin on the castor 

wheel (13)  into the designated mounting hole on the underside of the 

base (12). Firmly push the castor wheels (13) into the mounting holes  

(Fig B). 

   NOTE: Take care not to damage the castor wheel.  

They do not need to be forced into position.

3.   When all 4 castor wheels (13) are fitted, turn  

the product the right way up, and re-attach  

the appliance head (2) ensuring you align the  

notches on the ridge of the tank lip with the  

side locking handles, and secure the 2 side  

locking handles (6) in position (Fig C).

Assembly of the Carry Handle

1.   Place the carry handle (1) in the grooves on  

the top of the appliance head (2) so that they 

are fitted and align correctly (Fig D).

2.   Using a phillips screwdriver, insert and secure 

the screws through each side of the handle until 

secure (Fig E). 

Assembly for Dry Vacuuming –  

HEPA Filter

WARNING: Never use the vacuum without 

a filter. Check that the filter is securely fitted 

at all times. 

The Wet and Dry Vacuum is fitted with the HEPA 

filter (16) used for dry vacuuming upon purchase.  
To continue assembly for dry vacuuming, continue 

to the ‘Fitting the flexible hose’ section on page 15. 

Assembly

Assembly

Assembly

B.

D.

A.

C.

Notch

E.

Tighten

Summary of Contents for 61406

Page 1: ...ll safety warnings and all instructions thoroughly before operating this product Ensure you keep your manual in a safe place for future reference IM ed 7 06 2018 MODEL No MWW706S 35L 1200WC PRODUCT No 61406 61406 2400WWET DRY VACUUMWITH POWERTAKE OFF ...

Page 2: ...out more about the Aldi product you have purchased Pack Contents Parts 2 Description of Symbols 3 General power tool safety warnings 4 Specific Safety Instructions 8 Parts List 10 Assembly 12 Assembly of the wheels 12 Assembly of the Carry Handle 13 Assembly for DryVacuuming HEPA Filter 13 Assembly forWetVacuuming Foam Filter 14 Fitting the Flexible Hose 15 Fitting the extension tubes and tools 16...

Page 3: ...y household vacuuming as this will cause premature damage IMPORTANT INFORMATION NOTE First time users or inexperienced operators pay particular attention to the operation of the 2400W Wet and Dry Vacuum including details of assembling and preparation on pages 10 16 Operation on pages 16 21 and maintenance procedures on pages 22 23 Contents of carton 2 3 Description of symbols The rating plate on y...

Page 4: ...ectrical safety a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is increased risk of electric shock if your body is grounded c Do not expos...

Page 5: ...source and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in ...

Page 6: ...s to corrode Do not vacuum up any toner dust which is used in printers copiers and fax machines for example because it is electrically conductive In addition it is possible that it will not be completely filtered out by the filter system of theWet and DryVacuum and can be released into the air via the exhaust fan This appliance is NOT suitable for vacuuming fine dust which can be harmful to health...

Page 7: ...arry Handle 2 Appliance head 3 ON OFF switch 4 AC outlet socket 5 On board storage holders 6 Side Locking handle x2 7 Flexible Hose Outlet Suction 8 Flexible Hose Outlet Blower 9 Power cord 10 Tank 11 Drain Screw 12 Base 13 Castor wheels x4 14 Filter basket 15 Floating Safety Valve 16 HEPA filter 17 Flexible Hose 18 Extension Tubes x3 19 Foam Filter 20 Floor Tool 21 Crevice Tool 1 2 14 16 5 8 9 19...

Page 8: ... x side locking handles 6 pulling them outwards then upwards Fig A Then turn the tank 10 upside down 2 Fit the 4 x castor wheels 13 by inserting the mounting pin on the castor wheel 13 into the designated mounting hole on the underside of the base 12 Firmly push the castor wheels 13 into the mounting holes Fig B NOTE Take care not to damage the castor wheel They do not need to be forced into posit...

Page 9: ...PORTANT The Wet and Dry Vacuum should only be connected to a mains power supply socket an RCD Residual Current Device is recommended 4 Re assemble the appliance head 2 back onto the tank 10 and secure the 2 x side locking handles 6 NOTE Always unplug the appliance after use and before cleaning or changing the filters or accessories Fitting the Flexible Hose Connect the flexible hose 17 to the flex...

Page 10: ...y vacuuming applications IMPORTANT The Wet and Dry Vacuum should only be connected to a mains power supply socket an RCD Residual Current Device is recommended 1 Ensure the tank 10 is completely dry and free from dust and dirt 2 Only use the HEPA filter 16 for dry vacuuming applications Fig R Ensure you have already fitted the flexible hose 17 extension tubes 18 and if required the floor tool 20 o...

Page 11: ... requirement of up to 1200 Watts and only using one tool connected at a time To establish the power draw of your AC electric power tool refer to the rating technical label on the tool per example FigY WARNING Check the HEPA filter 16 regularly for any blockages which may reduce the suction and cause motor overheating If the vacuum noise changes immediately switch off the appliance by pressing on t...

Page 12: ...a pre set delay 5 When you have finished your task press O on the ON OFF switch 3 Fig AE WARNING Check the tank 10 regularly and empty the waste collected when it is about 2 3 full AA AB AC Z AD AE AF WARNING Check the HEPA filter 16 regularly for any blockages which may reduce the suction and overheat the motor If the vacuum noise changes immediately switch off the appliance and check the HEPA fi...

Page 13: ...pliance head 2 in water or allow water to enter the appliance head 2 Do not use cleaning agents or solvents These may be aggressive to the plastic parts on the appliance Cleaning theTank The tank 10 can be cleaned with a damp cloth and soap or rinsed under running water depending on the amount of dirt Wipe down and dry before storing away Cleaning the HEPA Filter Clean the HEPA filter 16 regularly...

Page 14: ...t and DryVacuum making it easy to maintain and operate Use onlyWORKZONE TITANIUM replacement parts for your product Non conforming parts or modifications made to parts will void your warranty Environmental protection Recycle unwanted materials instead of disposing of them as waste All tools hoses and packaging should be sorted taken to the local recycling centre and disposed of in an environmental...

Page 15: ...ted full with waste and debris Completely empty tank 10 Noise of vacuum changes and suction decreases HEPA filter 16 dirty and clogged Clean the HEPA filter 16 regularly by carefully patting it and cleaning it with a fine brush or hand brush not supplied If suction continues to decreases after cleaning the filter replace with a new HEPA filter Foam filter 19 is dirty and clogged Clean the foam fil...

Page 16: ...roducts are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China WORKZONE TITANIUM is a registered trademark of ALDI Stores...

Reviews: