background image

2 of 8  

Line of Sight  |  (800) 463-7731  |  los.workriteergo.com

 1 

  Remove Front and Rear Panels, Set Power Cord Aside

1.1  Remove the Front and Rear Panels from the Chassis (A) by 

turning the Panel Locks a quarter turn towards the center 

of the panel (inward), then pivot the panels forward to 

remove.

If you have Locking Panels, unlock using the included key.

1.2  Keep the protective tape around panels and on frame 

until assembly is complete to protect finish.

 2 

  Attach Top Brackets

Attach the Left Top Bracket (B) and Right Top Bracket 

(C) to Chassis (A) with the four 5/16"-18 Locknuts (D). 

Threaded studs on the brackets insert through holes in 

the Chassis and are held in place with the Locknuts.

Removable Panel

Locking Panel

 3 

  Attach Lid Stops to Worksurface

Note: Build Assembly in a large, clean area on carpeting or 

moving blankets to prevent damaging Worksurface and Lid. 

3.1  Place Worksurface (E) and Monitor Bay Lid (F) upside down on 

floor. Slide Monitor Bay Lid (F) into cutout in Worksurface (E).

3.2  Attach both Lid Stops (G) with eight #10-¾" Phillips Pan Head 

Screws (H). 

A

B

C

F

C

D

D

1.2

1.1

1.1

3.1

3.2

Front 

Panel

Threaded 

Studs

Rear 

Panel

Panel 

Lock

Protective 

tape

Under Top Bracket

E

G

H

H

  #10-¾" Phillips Pan 

Head Screws

Hardware at actual size

D

  5/16"-18 Serrated Flange Nut

Hardware at actual size

Summary of Contents for Line of Sight LOS3-B-M11 Series

Page 1: ...e vis est enterèe ATENCIÓN Éste producto està cargado con resortes y puede abrise con extrema fuerza cuando se remueve éste tornillo CAUTION Do not opperate without proper counterbalance weights in place Personal injury and or damage could occur MISEENGARDE Ne faites pas fonctionner sans des contrepoids appropriès en place Blessures et ou des dommages pourraient survenir ATENCION No operar sin los...

Page 2: ...th the four 5 16 18 Locknuts D Threaded studs on the brackets insert through holes in the Chassis and are held in place with the Locknuts Removable Panel Locking Panel 3 Attach Lid Stops to Worksurface Note Build Assembly in a large clean area on carpeting or moving blankets to prevent damaging Worksurface and Lid 3 1 Place Worksurface E and Monitor Bay Lid F upside down on floor Slide Monitor Bay...

Page 3: ...H four screws per Top Bracket B C 5 2 Note Chassis models over 48 have a Center Support which requires two 10 Phillips Head Screws H into the Center Support 5 3 Attach Monitor Bay Lid to both Monitor Lid Hinges with two 10 Phillips Head Screws H per hinge at the forward location You will finish installing the hinges in Step 10 when workcenter is right side up and you can more easily access the two...

Page 4: ...ay open with extreme force when screw is removed MISE EN GARDE Le produit est à ressort et peut s ouvrir avec un force extrème lorsque cette vis est enterèe ATENCIÓN Éste producto està cargado con resortes y puede abrise con extrema fuerza cuando se remueve éste tornillo CAUTION Do not opperate without proper counterbalance weights in place Personal injury and or damage could occur MISEENGARDE CAU...

Page 5: ...tely when released If lid doesn t close completely turn Adjustment Screw counter clockwise slightly until lid closes softly and completely when released 9 Raise Monitor Lift 9 1 Lift Lid fully open 9 2 Press down on PUSH HERE label on top of the Manual Lifts CAUTION Spring loaded mechanism Take care during the first time Monitor Arm is activated With no monitors in the Monitor Mount the mechanism ...

Page 6: ...crews that came with the monitor for Step 12 1 12 1 Attach VESA Plate M to the back of your VESA compatible Monitor with Spacers O Screws P Q R and Washers S or use the screws that came with your monitor Always use the shortest screws possible so you do not damage your monitor 12 2 Attach the VESA Bracket Monitor Assembly as high as possible on the Monitor Lift using two 20 Button Head Screws N an...

Page 7: ...ling to complete your installation according to the manufacturers specifications and your specific application 14 Install Power Distribution Options for Your Configuration With the Workcenter built you will now need to add your power options for your specific configuration Follow the instructions that came with the Power System Options to complete your configuration If you did not purchase the Pow...

Page 8: ...g agents Non abrasive spray cleaning agents Dawn Fantastik Windex Lysol Furniture spray Pledge Stain removers Lestoil Clorox Painted steel parts Clean surfaces regularly with damp cloth If necessary use a spray cleaning agent e g Fantastik sparingly Wipe completely dry with a soft rag using a straight line motion Lightly brush both vertical and horizontal surfaces to prevent dust build up Polished...