background image

2 of 11                                                                                                                        Workrite Ergonomics  |  800.959.9675  www.workriteergo.com

S A V E   T H E S E   I N S T R U C T I O N S

WARNING:

 

Maximum equipment loading of table assembly in addition to specified top is as follows:

  

    

  

Maximum top weight: 128 lb (58.2 kg)

 

    

  

Maximum 2 Stage (ST2E-XXXX-XXXXEOC-XX-XX-X) Equipment Load: 200 lb (90.7 kg)

 

    

  

Maximum 3 Stage (ST3EXXXX-XXXXEOC-XX-XX-X) Equipment Load 250 lb (113.6 kg)

 

Loading should be evenly distributed over table surfaces.

V = 120 VAC, 60 Hz / 4 A maximum

FLAMMABILITY: All worksurfaces used must meet UL 962 flammability requirements

  

  

Flame Spread Rating maximum 200 

  

  

Smoke Developed Index maximum 450

WORKSURFACE MATERIAL: This frameset is designed to accommodate worksurfaces made from Industrial Particle Board with nominal thickness 

of 1.125". If the worksurface is not appropriate or not mounted correctly to the table, it could cause the complete table to be unstable, it may collapse, 

and for an adjustable table, the electrical components may fail.
Intended for indoor use only.

For commercial use only

IMPORTANT SAFETY INSTRUCTIONS:

When using an electrical furnishing, basic precautions should always be followed, including the following:

Read all instructions before using this Sentinel Work Center.

DANGER:

 

To reduce the risk of electric shock, always unplug this Sentinel Work Center from the electrical outlet before cleaning or servicing. 

WARNING:

 

To reduce the risk of burns, fire, electric shock, or injury to persons:

1.  Unplug from outlet before putting on or taking off parts.

2.  Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.

3.  Use this Sentinel Work Center only for its intended use as described in these instructions, do not use attachments not 

recommended by the manufacturer.

4.  Never operate this Sentinel Work Center if it has a damaged cord or plug, is not working properly, has been dropped or 

damaged, or dropped into water. Return the furnishing to a service center for examination and repair.

5.  Keep the cord away from heated surfaces.

6.  Do not operate outdoors.

7.  Do not operate where aerosol (spray) products are being used or where oxygen is being administered.

8.  To disconnect, remove plug from outlet.

9.  Do not exceed maximum load recommendations.
Polarized Plug Instructions (Only applicable to products having a polarized plug power cord):

Some products include a polarized plug—see Figure A (One A/C plug blade wider than the other)—to reduce the risk of 

electrical shock. A polarized plug only fits a polarized power outlet one way. If the polarized plug does not fit properly into the 

electrical outlet turn the power plug over to see if it then fits properly and fully into the outlet. If the plug does still does not fit 

the outlet, contact a certified electrician to install the correct matching polarized electrical outlet. 

Caution: Never modify the power cord plug in any way
Double-Insulated Products Instructions: 

Some products are double-insulated. No means of grounding is required or provided on a double-insulated product; nor is a 

means for grounding to be added to the product. The plug in a double insulated system is shown in Figure A. Double-insulated 

products are indicated with markings of “double-insulated” or the “double box symbol”    

 

or both.

Grounding Instructions (For grounded electric products only):

Products with grounded power cords are for use on a nominal 120 V circuit and has a grounded plug as shown in Figure B  

Make sure the product is connected to an electrical outlet having the same configuration as the plug shown in Figure C.

Caution: Never modify, remove, or use adaptors that eliminate the ground connections from the grounded power cord
A/C Power:

Products sold in North America and other regions are 120 V A/C as marked on the power supply/control box of the furnishing 

and are to be used on a normal 120 V A/C circuit. Always follow the instructions above for power connection using grounded or 

double insulated power cords as supplied.

•  Only use power cord(s) supplied with your electric product

•  Never modify, alter, use an adaptor, or change the electrical system of this product in any way. 

Warning: Doing so may cause risk of electrical shock or fire

Illustration Disclaimer—Power Plug and Receptacle Images:

In some cases, the images in this instruction may not match the power cord supplied with your electrical furnishing based on your region. 

Plug type, blade size, and shape may change.

Grounding Pin 

Figure B

Grounded Outlet  

Figure C

Polarized Plug 

Figure A

Summary of Contents for ST2E-5472-4272EOC Series

Page 1: ...mm Flat Head Allen Screw Qty 16 P 8 Phillips Pan Head Screw Qty 17 Q 12 Phillips Pan Head Screw Qty 61 OM8 1 25P 20 mm Flat Head Allen Screw Qty 6 T 4 mm Allen Wrench Qty 1 U5 mm Allen Wrench Qty 1 S P Loop Qty 15 V Glide Qty 4 WCorner Glide Qty 1 X Corner Glide Adjuster Qty 1 R Cable Spool Qty 3 Tools Required Worksurface Required Sold Separately Cordless Drill 2 Phillips Bit Screwdriver or Drive...

Page 2: ...nistered 8 To disconnect remove plug from outlet 9 Do not exceed maximum load recommendations Polarized Plug Instructions Only applicable to products having a polarized plug power cord Some products include a polarized plug see Figure A One A C plug blade wider than the other to reduce the risk of electrical shock A polarized plug only fits a polarized power outlet one way If the polarized plug do...

Page 3: ... width of your work center ASSEMBLE REAR CONNECTED STRETCHER BRACKET 1 1 1 Hardware at actual size N M6 1 0P 12 mm Flat Head Allen Screw To avoid stripping the threads always insert and make the first few turns of the screw BY HAND with an Allen wrench T ensuring it is in straight NOTE Only use the M6 1 0P 12 mm flat head Allen screw N for assembly 52 58 Work centers 64 Work centers 70 Work center...

Page 4: ...widths Note Brackets can be sized in 3 increments for any non Workrite top Use with 42 54 widths Assemble rear brackets J to connector bracket K using M6 1 0P 12 mm flat head Allen screws N and tighten securely with the 4 mm Allen wrench T Use this guide below to determine the correct holes for mounting based on the width of your work center Note Left hand assembly for use on left end of top shown...

Page 5: ...ote Right hand connected stretcher assembly shown Reverse connected and floating stretchers for left hand assembly Note The right bracket will be on the left and left bracket on the right when upside down Attach the connected stretcher bracket K to the rear of the legs A with two 2 M6 1 0P 12 mm flat head Allen screws N as shown and tighten securely with the 4 mm Allen wrench T Attach the corner m...

Page 6: ...e worksurface Using the drill bit drill deep pilot holes in the six corner locations Note We recommend you mark your drill bit at to prevent drilling too deep Caution Do not drill through the worksurface Install six 6 12 Phillips pan head screws Q into the 6 corner locations and tighten securely Warning Do not over tighten and strip the screws into the top Using the drill bit drill deep pilot hole...

Page 7: ...nto corner foot ATTACH FEET 5 1 5 2 5 3 Choose the switch location for either right or left hand installation Note Right is on the left when table is upside down Place the switch B as shown and drill deep pilot holes with a 3 32 drill bit Measure and mark the switch location with a pencil on the top using the dimensions shown Install two 2 8 Phillips screws P and tighten securely ATTACH SWITCH 6 1...

Page 8: ... leg and the power supply Drill deep pilot holes with the drill bit for each cable spool Attach the power supply to the top using two 2 12 Phillips pan head screws Q and tighten securely Attach each cable spool R to the top using one 1 12 Phillips pan head screws Q and tighten securely ATTACH POWER SUPPLY CABLE SPOOLS TO WORKSURFACE 7 1 7 3 7 2 7 4 7 7 2 7 3 7 3 7 3 7 4 7 4 7 4 Q 12 Phillips Pan H...

Page 9: ...location it is to be used Plug the table into a 120 V outlet The Sentinel table will take a few seconds to self initialize You will hear a few beeps and the table will be ready to operate Route the switch cable around the nearest cable spool to take up extra cable length and plug it into the power supply Place P loops S on the switch and leg cables to secure them under the top as shown and drill d...

Page 10: ...the reset the table should operate as normal Repeat starting with Trouble Shooting Step 1 if the table still does not operate properly If you still have problems with your table please contact Workrite Ergonomics at 800 959 9674 Press 2 for Technical Support or contact us at customerservice workriteergo com With this function you can reset the Sentinel series switches to their original factory set...

Page 11: ...ons 3 While holding the UP and DOWN buttons reconnect the 120 V power cord to the power supply Note If your Sentinel Base has more than one power supply all power cords must be reconnected in this step 4 UP and DOWN buttons 5 Press the DOWN button until the table moves and stops The Restore Factory Settings step is now complete Down Button Up Button LED indicator light Green Available Red Occupied...