8 of 8
Workrite Ergonomics | 800.959.9675 www.workriteergo.com
#1500211- Rev B
Initialize Legs
After all legs and the control are connected, and the power cord has been plugged in, hold the
down arrow on
the control until the legs make a short motion down and then back up. This initializes and synchronizes the
table legs.
Adjust Feet Guides
If necessary, adjust leveling guides on table feet to level the worksurface. Unscrew to increase height, screw in to
decrease height.
Cleaning instructions
To clean the legs, apply cleaner to a soft cloth.
Suggested cleaners: Windex or Formula 409.
Do not use solvents and do not saturate or spray cleaners directly to table base.
Hold down the down arrow until table
moves slightly upwards
Connect Power Cord to the Power Supply and put workcenter upright
Connect the Power Cord (R) to the Power Supply (S).
Turn the table over into an upright position.
Plug the Power Cord into the power outlet.
Never connect or remove leg or
control cables when power is
connected! Doing so will damage
the Control Leg.
You must complete
this initialization step
or your table will NOT
function properly.
10
11
b
9
a
c
✓
a
b
c
N
O
O