6
3
Page 23
2. Operating Guide
2.4 Setup Menu
2.4.7 Master/ Slave Mode
Several units can be linked in Master/Slave mode. The master and slave unit
must be defined when linking. The master unit only can send information out,
and the slave unit only receives information. In the linkup of several units,
only one master unit can be selected. The dimmers are not required to transmit
information each other. All of them shall be set as the master parts or slave parts.
2.4.8 Unit Number
Not used now. It is prepared for the new DMX norm or standard revised.
2.4.9 User Curve
Here the setup menu for USER CURVE 1 or 2 can be activated by
pressing the left button once.
Two individual brightness curves can be programmed. These curves can
be assigned to the dimmer channels.
Turn the encoder without pressing any button, input data changes within
0%~FF%(100%). At this time, the horizontal cursor changes back and
forth.
Holding down the right button and turning the encoder simultaneously
makes the output data change between 0% and FF%(100%).
3
1. Vista General
1.1 Vista Frontal
1
2 3 4
5
6
Módulo del dimmer de canal
Pagina 31