background image

 

DIGILINE MX MKII 

USER MANUAL 
VERSION 1.1

 

 

 

DIGILINE MX MKII 

     www.workpro.es

 

 

 

 

-

 

DSP Area: It is the area where the processing of the device's outputs is configured. 

 

 

 

Output selection field. Allows you to choose the output you want to work on. 
The parameters to be controlled will vary depending on whether an input or 
an output has been chosen. 
 

 

Gain. Allows you to control the volume or reverse the polarity of the selected 
output. 

 

 

EQUALIZER

There are 8 filters applicable to each of the outputs. To apply 

them, we must select the band (filter number), the type of filter, the 
frequency, the gain and the Q factor. It is also possible to apply a filter using 
the mouse and acting on the points that appear in the image and that 
represent the 8 available filters. 
 

4.1.1.

 

DSP                    

Summary of Contents for DIGILINE MX MKII

Page 1: ...DIGILINE MX MKII User Manual Version1 1 ...

Page 2: ...ions that must be followed strictly to ensure the installation or safe operation of the product This symbol notifies the user about the instructions that must be followed strictly to ensure the correct installation or operation of the product This symbol notifies the user about additional information or optional instructions WELCOME TO WORK PRO Thank you for choosing the WORK PRO DIGILINE MX MKII ...

Page 3: ...URES 3 3 DEVICE DESCRIPTION 4 Front Panel 4 Rear Panel 5 Connections 5 3 3 1 Inputs 5 3 3 2 Enabling MIC inputs 6 3 3 1 Outputs 6 4 SETTING THE DEVICE 7 Setting through WorkCAD3 Configurator 7 4 1 1 DSP 9 4 1 2 GPIOs 13 4 1 3 LMI input 16 4 1 4 Presets 17 4 1 5 Setup 18 Project saving and device syncing 19 ...

Page 4: ...gical audio inputs Number of inputs 8 balanced Mic or Line inputs Audio connector 4 x Euroblock 12 pin 3 81mm Input sensitivity Line 6 dBu Mic fixed gain 43 5 dB Analogical audio outputs Número de salidas 8 balanced outputs Conector de audio 2 x Euroblock 12 pin 3 81mm Audio processing 8 filters 2 High pass crossover filters Low Pass Weighted matrix of sum of inputs inputs Compressor Limiter Noise...

Page 5: ...istor 5 Vdc max GPO TTL 3 3V 30mA Others Main supply AC 90 264 V Consumption 50 W Dimensions 109mm 133 75mm 40 45 mm Weight 360 g 3 DEVICE DESCRIPTION Front Panel 1 Input Signal Clipping LEDs indicating the signal level at the input 2 Output Clipping LEDs indicating the signal level at the output 3 Power LED indicating that the device is on 4 LAN LED indicating that there is an Ethernet connection...

Page 6: ... Input Mic level input that allows actions to be taken when a certain threshold is exceeded 7 GPIOs General purpose digital inputs and outputs 8 RS 232 Port Serial port for thrid partty control 9 RJ45 connnector for LAN TCP IP connection through ethernet 10 AC Main supply 90V 264V Connections Digiline MX consists of 8 Line level inputs and 8 Mic level inputs which are summed by hardware The follow...

Page 7: ...wanted noise the Mic inputs are disabled if you want to use them they must be enabled with the jumpers supplied with your Digiline MX MKII To do this unscrew the top cover of your Digiline MX and include the necessary jumpers according to the inputs you want to enable 3 3 1 Outputs 3 3 2 Enabling MIC inputs ...

Page 8: ...on must be done using the WorkCAD3 Configurator software which you can download at the following link https www equipson es productos workcad 3 Setting through WorkCAD3 Configurator After configuring the device at the IP level and updating it if necessary see WorkCAD3 Configurator manual proceed with its configuration https www eafg es productos Docs Manuales WorkCAD3_Configurator_Manual_EN_1_2 _2...

Page 9: ...ar VIEW DSP button Allows you to choose the display of the processing fields GPIOs Allows you to access to GPIOs setup Presets button Allows the management of presets and device boot mode Setup It allows access to the configuration of certain functions other than audio management MASTER It allows the modification both graphically and numerically of the general volume control of the device In addit...

Page 10: ... depending on whether an input or an output has been chosen Gain Allows you to control the volume or reverse the polarity of the selected output EQUALIZER There are 8 filters applicable to each of the outputs To apply them we must select the band filter number the type of filter the frequency the gain and the Q factor It is also possible to apply a filter using the mouse and acting on the points t...

Page 11: ...GILINE MX MKII www workpro es 10 MATRIX In this section you can choose the weighted sum of inputs to be sent to each output The value of each entry can be entered both graphically and numerically For each input there is a Mute and Invert option ...

Page 12: ...his section you can apply crossover filters on the selected output We have high pass and low pass filter We must select the cutoff frequency 20Hz 20KHz filter order eighth maximum and filter type Butterworth Linkwitz Riley Bessel For Linkwitz Riley filters the orders increase two by two ...

Page 13: ... es 12 DYNAMICS A Limiter Compressor Gate is available for each output Enables Dedicated to the activation of the Limiter Compressor and Noise Gate Limiter Threshold Compressor Times Attack and Release times for the Compressor Ratios Ratios for Noise Gate and Compressor ...

Page 14: ...figure LMI Level Measure Input Allows you to configure the LMI input Events Actions that will occur when the GPIO is enabled or disabled Its use is associated with settings such as GPIs and LMI GPIO State Input GPIO is configured as GPI Output Active GPIO is configured as GPO with an initial state of 0V Output Inactive GPIO is configured as GPO with an initial state of 3 3V 4 1 2 GPIOs ...

Page 15: ...d Button to eliminate command Eliminate UDP OSC command previously selected Button to copy command Copy the selected command to the clipboard Button to paste command Paste the command copied in the clipboard to the OSC command list or overwrite the selected command Button to save commands Sabe the commands programation If you do not save the commands they cannot be executed later Test button Execu...

Page 16: ...nd Information that will appear when we close the command edit drop down OSC command that complies with the Open Sound Control protocol Pressing over button you can access to OSC command editor Device Method Filter Commands associated with the selected device In this case select Digiline MX Method Field to select the type of OSC command you want to execute Address OSC command path This field is au...

Page 17: ... execute commands when the signal level is at a certain level On activate Determines the commands that are sent when entering the threshold level On Deactivate Determines the commands that are sent when leaving the threshold level LMI Level Measure Input Allows you to configure the LMI input Enable Allows you to enable or disable the LMI input Low level High level Thresholds that determine the sen...

Page 18: ...guration in the selected preset EXPORT Allows you to export all presets to a file with the extension wpf3_dig_preset Information that is not stored in a preset will not be exported IMPORT It allows importing all presets from a file with the extension wpf3_dig_preset Startup preset Allows you to manage the boot mode of the device Last Loaded The device will boot from the last preset that was loaded...

Page 19: ...ptions other than signal processing Password Lock Allows you to configure the locking options Input Mixer Lock the mixer Limiters Lock the Dinamic section Crossovers Lock the CrossOve filter sectionr Output Gains Lock the output gain Equalizers Lock the equalizer GPIs Lock GPIOs section Store Presets Lock Presets section 4 1 5 Setup ...

Page 20: ...ption only suitable for Digiline 8 Disable Serial Port Allows you to disable the Serial Port UART Baudrate Allows you to change the serial port speed Apply Button to apply the entered changes Project saving and device syncing For the creation of offline or online projects and their subsequent synchronization with the device go to the section Device synchronization From the WorkCAD3_Configurator ma...

Page 21: ...DIGILINE MX MKII USER MANUAL VERSION 1 1 DIGILINE MX MKII www workpro es 20 ...

Page 22: ...DIGILINE MX MKII USER MANUAL VERSION 1 1 DIGILINE MX MKII www workpro es 21 ...

Reviews: