SAFETY INSTRUCTIONS 

1. Read this manual carefully. 

2. Follow all instructions and warnings. 

3. Only use accessories specified by WORK PRO. 

4. Follow the safety instructions of your country. 

5. Be careful with sound levels.

 

SYMBOLS 

 The following symbols are used in this document: 

This symbol indicates a potential risk of harm to a person or damage to the product. You 
can  also  notify  the  user  of  the  instructions  that  must  be  followed  strictly  to  ensure  the 
installation or safe operation of the product. 

 This symbol notifies the user about the instructions that must be followed strictly to ensure 
the correct installation or operation of the product. 

 

 This symbol notifies the user about additional information or optional instructions. 

 

WELCOME TO WORK PRO

 

Thank you for choosing the WORK PRO SCPRO 4A BL system. 

This document contains essential information on the use of the system. Read this document carefully to 
become familiar with the system. 

Please check the WORK PRO website regularly to download the latest version of the document and 
software updates: 

https://www.workpro.es/

 

 

 

Summary of Contents for BlueLine Digital MKII SCPRO 4A BL

Page 1: ...SCPRO 4A BL User Manual Version1 0 ...

Page 2: ... instructions that must be followed strictly to ensure the installation or safe operation of the product This symbol notifies the user about the instructions that must be followed strictly to ensure the correct installation or operation of the product This symbol notifies the user about additional information or optional instructions WELCOME TO WORK PRO Thank you for choosing the WORK PRO SCPRO 4A...

Page 3: ... MKII System 4 3 RECEIVERS 4 Audio extracting methods 5 3 1 1 DUAL 5 3 1 2 SINGLE 5 3 1 3 MONO 6 3 1 4 INVERT OUT 7 4 SCPRO 4A BL 8 Características 9 Description of the device 10 4 2 1 Puerto LAN 10 4 2 2 REMOTE 11 4 2 3 GPIOs 11 4 2 4 Analogic audio output 12 4 2 5 Amplified audio output 12 4 2 6 Main supply input 13 Device Setup 14 Accessories 15 ...

Page 4: ...nfrastructure in the installation due to its low bandwidth consumption On the other hand it is compatible with commonly used low or high impedance amplification systems Thanks to the modular design of the system BlueLine Digital MKII adapts perfectly to the features of each installation being able to expand the system in the future if the characteristics of the installation require it Features Man...

Page 5: ...mount controller for local receiver WNC 1 Wallmount controller through the network WAC 7 Customizable wallmount controller Note The BlueLine Digital MKII series is compatible with the previous series of devices so you can include devices of both series in your installation 3 RECEIVERS The BlueLine MKII receivers are devices that are responsible for extracting one stereo audio channel from the netw...

Page 6: ...from the network The extraction of this channel can be done in different ways that can be select in the configuration interface of WorkCAD3 Configurator Stereo extraction mode Each input is assigned to its output Individual extraction mode Of the two parts that one stereo channel is conformed 1 L or 2 R we choose one of them to extract it by both outputs of the receiver In this example we select 1...

Page 7: ...ITAL MKII SERIES www workpro es 6 Mono extraction mode The two input channels 1 L and 2 R are summed to extract them by both outputs of the receiver 6 dB are subtracted from each output to compensate for the electrical sum of two input channels 3 1 3 MONO ...

Page 8: ...ITAL MKII SERIES www workpro es 7 Inversion of the polarity for output 2 in order to create a balanced output or Bridge I the case of amplified output This option is only available for SINGLE and MONO modes In this case we select MONO mode 3 1 4 INVERT OUT ...

Page 9: ...ceiver with included amplifier With it you can extract one of the channels emitted by the Blueline Digital MKII transmitters Furthermore SCPRO 4A BL includes 1x GPI pull up and 1x GPO open collector The device can be powered by either PoE or an external power supply It must be emphasized that a receiver cannot mix or add channels from different streamers ...

Page 10: ...t Bridge mode 24Vdc 1x 40W 8 Ω Power output dual mode PoE 2x 5W 4 Ω Power output Bridge mode PoE 1x 10W 8 Ω Input sensitivity 0 7 dBu 840mVrms GPIO GPIs Pull Up resistor 5 Vdc max GPOs Open collector 12Vdc máx 1A máx Network Connector RJ 45 Audio over IP Datagrams BlueLine UDP Ethernet 100 Base TX Supply External source 12 24 Vdc Not included PoE Class Class 0 802 3af Consumption 31 5 W General Pr...

Page 11: ...ositive por mono balanced 6 GND Ground connection 7 OUT_R Right output line level for stereo mode or negative por mono balanced 8 5 UPPER Terminal Block From Left to Right 1 SPK_1 Positive to speaker 1 2 SPK_2 Positive to speaker 2 Negative in Bridge mode 3 GND Ground connection 4 SPK_1 Positive to speaker 1 5 GND Ground connection 6 24V DC Positive pin for main supply 7 GND Ground connection RJ45...

Page 12: ...I and 1 GPO GPI Input used to sense logical voltage variations so that UDP OSC control commands can be sent when they occur A typical configuration would be the connection of a push button between GPI and GND so that when it is pressed or clicked it can send OSC commands previously programmed through WorkCAD3 Configurator GPO Output in open collector configuration which once activated allows curre...

Page 13: ...o this keep in mind the following connection types STEREO UNBALANCED MONO UNBALANCED MONO BALANCED The output power of the device will depend on the type of power used If we want to obtain the maximum power we must supply it with an external 24Vdc source below the different powers offered are detailed according to the power and mode of use 4 2 4 Analogic audio output 4 2 5 Amplified audio output ...

Page 14: ...GE configuration so that the device will deliver all its power in a single output Remember that the minimum load in this mode of use will be 8 Ω We will choose the audio extraction mode through WorkCAD3 Configurator The different types of connection are detailed below according to the audio extraction mode DUAL BRIDGE 24VDC 2A power is required to deliver maximum amplifier power Check the correct ...

Page 15: ... to the zone to which the device belongs in order to receive OSC control commands By default all BlueLine receivers come in zone 1 Generate Ding Dong Button for the receiver to execute a Ding Dong signal This is useful to be able to recognize check the speakers connected to our receiver Channel Stereo audio channel number that we want to extract Controller s offset Field to enter an offset in the ...

Page 16: ...thods for more details Volume Dedicated field to control the volume and mute channels 1 2 and Master Banks Field dedicated to programming the GPIs of the device Bank GPI selection Event Selection of the command execution mode according to the high or low level of the signal associated with the GPI In the case of an On Activate closed switch On deactivate open OSC Methods Field dedicated to the inc...