More than 30% of all calls made to Worcester Heat Systems to

report appliance faults or breakdowns prove to be false alarms, as there
is often a simple explanation for the apparent malfunction.

So, to help you save time and money – not to mention frustration

and inconvenience – please refer to the General Information, Notes and
Lighting Instructions ensuring all controls are set correctly.

If, after following the instructions the appliance still fails to oper-

ate correctly call your local Worcester Heat Systems Service Centre.
Arrangements will be made for an engineer to call as soon as possible.

CALL-OUT CHARGES

All of our field service engineers are factory trained.

If you request a visit from an engineer and your appliance has

been installed within the last 12 months, no charge will be made for
parts and/or labour, providing:

The appliance was commissioned correctly on installation.

An appliance fault is found and the appliance has been

installed within the past 12 months.

A call-out charge will be made where:

The appliance has been installed for over 12 months, or

Our Field Service Engineer finds no fault with the appliance

(see note), or

The cause of breakdown is with other parts of your plumb-

ing/heating system, or with equipment not supplied by Worcester.

NOTE: 

Invoices for attendance and/or repair work carried out on

your appliance by any third party will not be accepted.

APPLIANCE FAILS TO

OPERATE

Summary of Contents for Highflow 400 Electronic Series

Page 1: ...HIGHFLOW 400 ELECTRONIC SERIES USER INSTRUCTIONS CUSTOMER CARE GUIDE G C NUMBERS APPLIANCE NATURAL GAS L P G Fanned Flue RSF 47 311 61 47 311 64 Balanced Flue BF 47 311 62 Open Flue OF 47 311 63...

Page 2: ...Electronic appliance offers you the very best of every thing quality efficiency economical running costs proven reliability and value for money What s more you also have the assur ance of our no nons...

Page 3: ...ating The hot water delivery rate is limited to 18 l m The specific rate declared as part of the relevant standard is 20 l m To achieve this a tank temperature of 75 C is required The appliances can o...

Page 4: ...When a demand is made for heating by the system controls i e a programmer or room thermostat The water diverter valve will open the pump will energise circu lating primary water around the heating sys...

Page 5: ...rly that this pressure is main tained and contact your installer or maintenance engineer if there is a permanent significant drop in pressure indicated on the gauge If the system loses pressure it sho...

Page 6: ...ntact Worcester Heat Systems Ltd HOT AND COLD FLOW If the flow of water demanded from both hot and cold service outlets is dependent upon mains supply it may not be possible in some installations to o...

Page 7: ...described in BS 6798 1987 CIRCULATING PUMP This may be fitted with a speed adjuster If so it will be factory set at maximum and should not be re adjusted FROST PRECAUTIONS If the appliance is not to b...

Page 8: ...he appliance facia panel Operating instructions are sup plied with the programmer TEMPERATURE CONTROLS The Heating Temperature Control gives control over the temper ature of water supplied to the radi...

Page 9: ...9 Fig 2 Facia panel Heating Temperature Control Minimum setting Maximum setting Optional Facia Mounted Programmer Power Light CH ON Light OFF HW ON Light Hot Water Temperature Control...

Page 10: ...entral heating temperature control B to the required position TO STOP THE APPLI ANCE For Short Periods Set the temper ature controls or programmer to OFF as indicated by the Demand lights F G going ou...

Page 11: ...relight automatically when the power supply is restored However depending upon circumstances it may be necessary to turn the Heating Temperature control OFF and ON before the appliance will operate I...

Page 12: ...CHARGES All of our field service engineers are factory trained If you request a visit from an engineer and your appliance has been installed within the last 12 months no charge will be made for parts...

Page 13: ...e it is essential that your boiler receives regular competent servicing and annual maintenance checks beyond the initial 12 month guarantee period Regular service contracts can be arranged with your i...

Page 14: ...01506 441 687 OPERATING HOURS Mon Fri 8 00am to 6 00pm Sat 8 30am to 1 00pm Please contact our UK Call Centre number where our friendly operators will book your call with one of our team of nationwid...

Page 15: ...ioned and where appropri ate the first 12 month service has been carried out to the satisfaction of Worcester Heat Systems Limited when requested 3 That any product or part thereof returned for servic...

Page 16: ...this will not affect your statutory rights in any way it will assist us to maintain an effective and efficient customer service by estab lishing a reference and permanent record for your boiler IMPORT...

Reviews: