Maintaining your boiler

Greenstar FS CDi 

ErP

– 6720818078 (2015/12)

5

Maintaining your boiler

Your new gas-fired boiler represents a long term investment in a reliable, high quality product.
To clean, wipe the boiler casing with a soft clean cloth. Please do not use chemical cleaning products which may damage the paint 
finish.
In order to realise its maximum working life, and to ensure it continues to operate at peak efficiency and performance, it is essential 
that your boiler receives regular annual servicing and maintenance checks during and beyond the guarantee period from a 
competent registered gas engineer, such as a Worcester service engineer or other Gas Safe registered engineer.
If your Greenstar gas-fired boiler should fail to operate correctly or requires servicing, please contact the Worcester, Bosch Group 
Appointments Team (see back cover for details).

Details of the boiler including the Gas Council number can be found on the front cover of these User Instructions and on the boiler 
identification label on the boiler fascia.
The Gas Council number is also listed on the front cover of your Installation, Commissioning and Servicing Instructions.

6

Fault  finding

In the event that the boiler stops functioning or does not perform as expected, you can carry out a few simple checks. The checks 
listed in the table below detail some of the possible causes. Should the problem persist or if other fault codes are displayed, then it 
will be necessary to contact the Worcester, Bosch Group.
This table gives information on basic operating system problems.

Problem

Cause

Remedy

EA fault code flashing 
on display

No gas supply/low gas supply pressure

▶ Contact your gas supplier.

Condensate outlet blocked

▶ If it is safe to do so, check your condensate pipe 

outlet for blockages, such as ice or foreign objects.

Flue blocked

▶ If it is safe to do so, check your flue outlet for 

damage or blockages.

Desired room 
temperature is not 
reached

Thermostatic radiator valve(s) set too low

▶ Increase thermostatic radiator valve setting(s)

Temperature control for central heating flow on 
boiler set too low

▶ Increase central heating flow temperature control 

setting

Air trapped in heating system

▶ Bleed radiators and recharge heating system

Boiler temperature controls set too low

▶ Increase settings on boiler controls

Desired room 
temperature too high

Radiators are too hot

▶ Turn down thermostatic radiator valves/room 

thermostat

▶ Reduce central heating temperature by turning 

down the Central Heating control on boiler

Heating stays on for 
too long

Timer/Programmer incorrectly set

▶ Check setting and adjust

ON/OFF Indicator is 
not illuminated

Momentary power failure

▶ Disconnect boiler supply, wait a few seconds then 

reconnect.

Hot water 
temperature too low

Cylinder thermostat temperature set too low 

▶ Check setting and adjust

Air trapped in heating system

▶ Bleed radiators and recharge heating system

Timer/Programmer incorrectly set

▶ Check setting and adjust

Hot water 
temperature too high

Cylinder thermostat temperature set too high

▶ Check setting and adjust

Table 1

Fault finding

Summary of Contents for Greenstar FS 30CDi ErP

Page 1: ...EALED OR OPEN VENT CENTRAL HEATING SYSTEMS 6 720 818 078 2015 12 The appliances are for use with Natural Gas or L P G Cat II 2H3P type C13 C33 C53 C93 Natural Gas FS 30CDi ErP Regular GC number 41 406...

Page 2: ...y efficient offering you economical running costs and value for money It sits in SEDBUK 2005 Band A scoring highly in SEDBUK 2009 and is therefore among the top energy rated boilers available There is...

Page 3: ...ved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Combustible and Corrosive Materials Chemically aggressive substances can...

Page 4: ...etedbytheinstalleratthetimeofinstallation Itconfirms that the boiler hasbeen installed and commissioned according to the manufacturer s instructions The logbook provides space for the recording of reg...

Page 5: ...oiler controls Boiler Controls 1 Master switch for ON OFF 6 Not used 2 Power ON and fault indicator blue 7 Central heating temperature control 3 Boiler display 8 Service Engineer button only 4 Reset b...

Page 6: ...0 Fig 3 Settings for the central heating temperature with approximate temperatures 3 2 1 Controlling the central heating Central heating systems must be controlled effectively using a programmer or ti...

Page 7: ...protection Leave master switch on 1 Turn the central heating temperature control 7 to frost protection 3 3 1 Frost protection for the heating system If remote pipe work is likely to be subject to free...

Page 8: ...ndicator 2 will stop flashing The boiler will function normally dependent on programmer and room thermostat settings 6720808851 05 1Wo 1 2 3 4 5 6 max reset eco 3 2 4 If the fault cannot be cleared by...

Page 9: ...ce with the addition of cupboards shelves etc next to the boiler item Minimum distance requirements for compartments 1 Overall height of compartment 2 Overall depth of compartment 3 Overall width of c...

Page 10: ...unventilated compartment or an airing cupboard then ventilation must be provided as described in BS 5440 A minimum of two air vents of equal size must be fitted one at low level and another at high l...

Page 11: ...yed then it will be necessary to contact the Worcester Bosch Group This table gives information on basic operating system problems Problem Cause Remedy EA fault code flashing on display No gas supply...

Page 12: ...up Appointments Team see back cover for details Contact your installer in order to find a permanent solution to the problem When calling Worcester Bosch Group you may be asked for the error code This...

Page 13: ...which our products are sold to ensure optimum recycling All of our packaging materials are environmentally compatible and can be recycled 9 Tips on energy saving Heating economically The boiler provid...

Page 14: ...f this boiler is fitted to a sealed system and water leaks are found or if excessive bleeding is required then a service engineer must be contacted to inspect the installation and rectify any fault On...

Page 15: ...ed by faulty installation neglect misuse or accidental damage or the non observance of the instructions contained in the Installation and Users Instructions leaflets viii that the appliance has been u...

Page 16: ...9 SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a bra...

Reviews: