INSPECTION AND SERVICE
NOTE: A service must NOT be
attempted if a CO/CO2
analyser is NOT available.
•
To ensure the continued efficient operation
of the appliance it must be checked at
regular intervals.
•
The frequency of servicing will depend upon
the particular installation conditions and
usage however, an annual service is
recommended .
•
The extent of the service required by the
appliance is determined by the operating
condition of the appliance when tested by
fully qualified engineers.
•
The service interval record sheet at the rear
of these instructions
must
be completed
after each service.
Inspection
1
Check that the terminal and the terminal
guard, if fitted, are clear and undamaged.
2
If the appliance is in a compartment or
cupboard check that the specified service
space around the appliance is clear. Refer to
page 11 for information.
3
Check all the joints and connections in the
system and remake any that show signs of
leakage. Refill and re-pressurise if
applicable as described in Commissioning.
Operate the appliance and take note of any
irregularities.
Refer to Fault Finding for rectification
procedures.
I M P ORTANT: Any service work
must be carried out by competent
registered engineers such as
British Gas or Corgi registered
personnel.
CAUTION:
TURN OFF THE GAS SUPPLY AND ISOLATE THE MAINS
S U P P LI E S B E FOR E STARTI NG ANY WOR K AN D OB S E RVE ALL
RELEVANT SAFETY PRECAUTIONS.
IMPORTANT:
AFTER REPLACEMENT OF ANY COMPONENTS ALWAYS
CHECK FOR GAS SOUNDNESS WHERE RELEVANT AND CARRY OUT
FUNCTIONAL CHECKS AS DESCRIBED IN COMMISSIONING.
ANY O -R I NG OR GAS K ET THAT AP P EAR S DAMAG E D M UST B E
REPLACED.
1
2
3
INSPECTION AND SERVICE
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR Ri
8 716 115 168a (06/2008)
32
S
E
RV
ICI
N
G
& S
P
AR
E
S