![Worcester GREENSOURCE 6 kW Installation Manual Download Page 42](http://html1.mh-extra.com/html/worcester/greensource-6-kw/greensource-6-kw_installation-manual_996561042.webp)
42
Technical information
Technical information
Output data at +7/35º and +7/45º are stated according to the European standard EN 14511.
1)
aM type fuse, D characteristic MCB. Both units require a means of electrical isolation.
2)
Dimensions excl. feet, supplied min 20 mm - max 30 mm depending on adjustment.
Greensource Hot water distribution unit
Control unit
Rego 800
Output electric element
kW
4,5
Output circulation pump
kW
0,2
Electrical supply
230V 1N~
Max. power consumption
kW
4,7
Fuse size
1)
AT
25
Max working pressure
bar (MPa)
2.5 (0.25)
DHW volume
l
151
CH Buffer volume
l
55
Expansion tank
l
12
Overheat protection
ºC
90
Min. fl ow heating system
l/s
0
Pump for heating system G1
Wilo Star RS 25/6-3
Heat carrier pump G2
Wilo Star RS 25/6-3
Dimensions (WxDxH)
mm
600/615/1660
Weight, excluding water
kg
122
Weight, including water
kg
347
Greensource
6 kW
7 kW
9.5 kW
Emitted/Supplied output at +7/35º
kW
5,5 / 1,5
7,1 / 2,1
8,8 / 2,3
Emitted/Supplied output at +7/45º
kW
5,1 / 1,7
6,9 / 2,5
8,5 / 2,8
Heat carrier fl ow nominal
l/s
0,19
0,29
0,34
Internal pressure drop heat carrier
kPa
5
6
7
Air fl ow
m³/h
2200
2200
2200
Electrical consumption fan
A
0,44
0,44
0,44
Electrical supply
230V 1N~
Fuse size
1)
AT
16
25
25
Compressor
Scroll
Highest outgoing heat carrier temperature
ºC
65
65
65
Refrigerant fi lling R-407C
kg
2
2,3
2,4
HTF connection, clamping ring
mm
Hose 1 inch internal thread
Defrost system
Hot gas with four-way valve
Operating temperature
°C
-20 – +35
Dimensions (WxDxH)
2)
mm
820x640x1190
Weight
kg
140
145
155
Outer casing
Galvanised enamelled plate
Summary of Contents for GREENSOURCE 6 kW