Dimensions, clearance and plumbing connections
Front
Left-hand side
1)
Flow to HWDU
.
Cable entr y
Dimensions, clearance and plumbing connections
Back
Condensator
drain
640
1190
60
820
411
220
105
101
165
201
Greensource Air to water heat pump (outdoor)
Hot water distribution unit
Required installation space for the HWDU.
A free space of 600 mm is required in front of the HWDU. No clearance
required at the sides.
A minimum of 25 mm is required from the back of the unit to any
permanent fi xture: i.e. outer wall or partition wall.
Min. space 1,240 mm
Wall
Insu-
lated
wall
Front
Min. 25 mm
Min. 600 mm
HWDU
Required installation space for the heat pump.
Minimum distance from the pump to the wall is 300 mm.
Minimum distance in front of the pump 1000 mm, to the sides 500 mm.
If a roof is installed it must be positioned at least 1.5 m above the heat
pump to avoid the recirculation of cold air.
2)
Return from HWDU
Note
The waste coupler must be fi tted to
the condensator drain oulet.