PRE-INSTALLATION
6 720 803 599 (2012/06)
16
3.8
FLUE OPTIONS
The Greenstar CDi has the option of three horizontal RSF (60/100
telescopic, 60/100 longer telescopic and 80/125 telescopic) flue
system and two vertical RSF (60/100 or 80/125) regular flue systems:
The systems have different maximum flue lengths
This page and the next page show various flue options with the maximum
straight flue lengths required to achieve the maximum flue length.
Maximum horizontal flue lengths (L)
Boiler model
100mmØ
125mmØ
29CDi
7,000mm
16,000mm
34CDi
7,000mm
16,000mm
38CDi
6,500mm
17,200mm
42CDi
6,000mm
12,500mm
Maximum vertical flue lengths (L)
Boiler model
100mmØ
125mmØ
29CDi
8,000mm
16,000mm
34CDi
8,000mm
16,000mm
38CDi
8,000mm
18,400mm
42CDi
7,500mm
16,000mm
NOTICE:
60/100 Flue systems:
B
Each 90° bend used is equivalent to 1.5 metres of
straight flue.
B
Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE:
80/125 flue systems:
B
Each 90° bend used is equivalent to 2 metres of
straight flue.
B
Each 45° bend used is equivalent to 1 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
125mmØ
29CDi
570mm
600mm
34CDi
570mm
600mm
38CDi
570mm
600mm
42CDi
570mm
600mm
Horizontal extended flue
Flue option 2
100mmØ
125mmØ
29CDi
7,000mm
16,000mm
34CDi
7,000mm
16,000mm
38CDi
6,500mm
17,200mm
42CDi
6,000mm
12,500mm
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
125mmØ
29CDi
5,500mm
14,000mm
34CDi
5,500mm
14,000mm
38CDi
5,000mm
15,200mm
42CDi
4,500mm
10,500mm
Horizontal extended flue with 2x90° bends
Flue option 4
100mmØ
125mmØ
29CDi
4,000mm
12,000mm
34CDi
4,000mm
12,000mm
38CDi
3,500mm
13,200mm
42CDi
3,000mm
8,500mm
High level horizontal extended flue
Flue option 5
100mmØ
125mmØ
29CDi
7,000mm
16,000mm
34CDi
7,000mm
16,000mm
38CDi
6,500mm
17,200mm
42CDi
6,000mm
12,500mm
High level horiz. extended flue with 2x90° bends
Flue option 6
100mmØ
125mmØ
29CDi
4,000mm
12,000mm
34CDi
4,000mm
12,000mm
38CDi
3,500mm
13,200mm
42CDi
3,000mm
8,500mm
High level horiz. extended flue with 3x90° bends
Flue option 7
100mmØ
125mmØ
29CDi
2,500mm
10,000mm
34CDi
2,500mm
10,000mm
38CDi
2,000mm
11,200mm
42CDi
1,500mm
6,500mm
Vertical balanced flue assembly
Flue option 8
100mmØ
125mmØ
29CDi
8,000mm
16,000mm
34CDi
8,000mm
16,000mm
38CDi
8,000mm
18,400mm
42CDi
7,500mm
16,000mm
Vertical balanced flue with 2x90° bends
Flue option 9
100mmØ
125mmØ
29CDi
5,000mm
12,000mm
34CDi
5,000mm
12,000mm
38CDi
5,000mm
14,400mm
42CDi
4,500mm
12,000mm
Vertical balanced flue system with 2x45° bends
Flue option 10
100mmØ
125mmØ
29CDi
6,500mm
14,000mm
34CDi
6,500mm
14,000mm
38CDi
6,500mm
16,400mm
42CDi
6,000mm
14,000mm