COMMISSIONING
Greenstar i System Compact - 6 720 807 726 (2013/05)
33
5.4.1
BOILER START UP SCREENS
On initial start up, the following screens are displayed:
1. All the symbols are displayed for approximately two seconds.
2. The control will run an internal test.
3. When the internal test has been successfully performed, this screen is
displayed:
– The boiler is in stand-by.
– The flow temperature sensor indicates the primary temperature
from the heat exchanger (not the target set point).
Fig. 57 Boiler start up screen
▶ If no adjustments are made for 30 seconds the back light is turned off.
▶ As soon as an adjustment is made, the screen will light up and the
relevant information will be displayed.
▶ If the Eco button
is pressed or the Hot water temperature control
is adjusted the boiler display will show N/A to indicate that these
functions are not available without the optional integral diverter valve.
Fig. 58
STATUS CODES
Refer to section 7.5 for Status codes and service menus.
These are not faults, but provide information concerning the current
status of the boiler.
During normal boiler operation various Status codes can be displayed by
pressing the
button.
The first screen of the Information menu displays the current Status
code, this will change as the boiler runs through various modes and
sequences.
°C
°F
°C
°F
°C
°F
6720807726-07.1W
o
~2 s
1.
2.
3.
eco
°C
°F
N/A
6720646608-31.1W
o
SCREEN DISPLAY
DESCRIPTION
All possible screen symbols
This screen is displayed briefly
during boiler start up and shows
all the symbols that could be
displayed.
Alpha/Numerical display
Displays a temperature or
boiler status code.
Text display
Displays PreHeat or Eco, or
diagnostic code
Hot water
Displays this symbol during a
DHW demand.
Central Heating
Displays this symbol during a
CH demand.
Chimney sweep mode
Displays during service when
the boiler is set to maximum or
minimum output.
Alert
Displays with the boiler status
code and diagnostic code
during a fault condition.
Service mode
Displays when a qualified
service engineer is in the
service menus.
Burner on
The boiler is in operation and
the flame is alight.
Centigrade
Displays next to the
temperature reading.
Confirmation
This symbol confirms a manual
change.
Table 12 Symbol description
°C
°F
°C