5
Available pump head.
Boiler output.
Head
Min, flow rate
Temperature rise
across heating flow
kW
Btu/h
Metres
Feet
L/min.
Gal/Min.
and return
6.7
(22,860)
5.4
17.8
8.7
1.9
11°C (20°F)
7.2
(24,566)
5.7
18.8
5.1
1.1
20°C (37°F)
24.0 (81,888) 2.0 6.6 23.0 5.1 15°C (27°F)
26.0 (88,712) 3.5 11.6 18.6 4.1 20°C (37°F)
Table 3
Non-cond.
Condense
Non-cond.
Condense.
Mode of
operation
Specifications
Central heating flow fitting.
22mm Compression
Central heating return fitting.
22mm Compression
Cold water mains inlet fitting.
15mm Compression
Domestic hot water outlet fitting.
15mm Copper
Condensate drain connection.
22mm (
3
/
4
in Plastic)
Gas inlet fitting.
Rc
3
⁄
4
Pressure relief valve discharge fitting.
15mm Copper
Overall height (including flue turret).
1000mm (39.4 inches)
Casing height.
850mm (33.5 inches)
Casing width.
450mm (17.7 inches)
Casing depth.
360mm (14.2 inches)
Weight (including water).
50 kg
Installation weight.
47 kg
Pakaged weight.
53 kg
Primary water capacity.
2.0 litres (0.45 galls)
Maximum cold supply pressure.
10 Bar (150 psi)
Minimum cold supply pressure (working) for max. hot water flow.
1.2 bar
Minimum cold supply pressure (working) to operate appliance.
0.7 bar
Maximum central heating flow temperature.
Nominally 82°C (180°F)
Output to domestic hot water
Modulating 6.7 to 24.0 kW
Output to central heating - None condensing mode. Modulating 6.7 to 24.0 kW
Output to central heating - Condensing mode. Modulating 7.2 to 26.0 kW
Maximum domestic hot water flow rate (from the appliance).
Nominally 8.0 litres/min
Equivalent domestic hot water flow rate to give a temperature rise
Nominally 11.5 litres/min
of 30°C (specific rate).
Equivalent domestic hot water flow rate to give a temperature rise
Nominally 9.8 litres/min
of 35°C.
NOX Classification
Class 3
Appliance Flue Types
C12 C32
Table 4