The appliance is supplied suitable for fitting to a sealed
primary system only.
Refer to fig. 15.
IMPORTANT
Two flue options are available:
i) Standard Flue
To suit rear or side flue installations where the flue length
measured from the appliance casing to the outside of the wall
is from 100mm to 1000mm.
ii) Extended Flue
To suit rear or side flue installations where the flue length
measured from the appliance casing to the outside of the wall
is up to 2000mm.
Before continuing the installation it is essential to ensure the
correct flue assembly is available.
Each flue assembly comprises:
Appliance casing sealing gasket.
Flue turret.
Air duct of appropriate length.
Flue terminal with flue duct, of appropriate length, attached.
Tube of silicon sealant.
Four fixing screws.
(Air duct support bracket, optional extra, part No 7 716 191 024).
Flue system notes:
i) Flue incline
The flue assembly must be installed with an incline of 2
1
/
2
°
(44mm per metre length). The incline must fall towards the
appliance.
Refer to Section 3, Table 2 and fig. 15.
ii) Installation Standard
The flue must be installed as specified in BS 5440 Pt.1.
NOTE: Read this section fully before commencing the
installation.
Check the appliance carton contains:
The correct appliance.
Installer’s instruction pack.
User’s instruction pack.
Pre-plumbing manifold.
Wall plate cross member.
Installer’s hardware pack.
Remove the packaging from the appliance leaving it to stand
upright on the polystyrene plinth.
Using the two M4 thread forming screws supplied in the
hardware pack assemble the wall plate cross member to the pre-
plumbing manifold. See fig. 16.
Check the position chosen for the appliance is in accordance
with the instructions given in Sections 4 and 5. Also refer to fig. 2.
Hold the wall plate on the wall onto which the appliance is to be
fitted. Check the wall plate is horizontal. See fig. 16.
Ensure the plastic cover, over the valves and ‘O’ rings, is left in
place. The cover will protect the valves and ‘O’ rings against
ingress of dirt and dust.
Mark the position of the fixing holes. Two at the top and four
locating the pre-plumbing manifold onto the wall.
Mark the position of the appliance centre-line, from the ‘V’
formed by the wall plate cross member, onto the wall.
Draw a horizontal line along the top of the wall plate cross
member. See fig. 16.
Rear Flue Installation
Draw the appliance vertical centre-line on the wall ensure the line
passes through the ‘V’ previously marked.
Measure upwards, along the vertical centre-line, 800mm from
the horizontal line and mark the point. This is the
rear flue
centre point position
for the flue duct hole. See fig. 16.
Side Flue Installation
Extend the line from the rear flue centre point position,
previously marked, along the appropriate wall.
The line must incline downwards 2
1
/
2
° (44mm per metre
length) towards the appliance.
Measure 197mm from the junction of the walls and mark a short
vertical line. Extend horizontally the side flue line to intersect the
vertical line and mark the point.
This is the
side flue centre point position
for the flue duct hole.
See fig. 16.
10.2 General Fitting
10.1 Flue Options
10. Installation
14
Fig. 15. Flue Options
Rear flue
length 100 to
390mm
2
1
/
2
¡
NOTE: Flue system
inclines downwards
towards the appliance
2
1
/
2
¡
Side flue left or right
length 100 to 360mm
Appliance
Standard Flue
2
1
/
2
¡
NOTE: Flue system
inclines downwards
towards the appliance
2
1
/
2
¡
Side flue left or right
maximum length 2000mm
Rear flue
maximum length 2000mm
Appliance
Extended Flue
Summary of Contents for 26CDi Xtra
Page 35: ...35 96 NG OR LPG NG OR LPG 109 201 ...
Page 47: ...47 ...