Manual 37351A
MFR 11 Packages - Protection Relay
© Woodward
Page 49/59
Relay
outputs ----------------------------------------------------------------------------------potential free
- Contact material....................................................................................................... AgCdO
- General purpose (GP) (V
Cont, relay output
)
AC .................................. 2.00 Aac@250 Vac
DC ....................................2.00 Adc@24 Vdc
0.36 Adc@125 Vdc
0.18 Adc@250 Vdc
- Pilot duty (PD) (V
Cont, relay output
)
AC ..................................................................
DC ....................................1.00 Adc@24 Vdc
0.22 Adc@125 Vdc
0.10 Adc@250 Vdc
Housing ---------------------------------------------------------------------------------------------------------
- Type........................................................................................... APRANORM DIN 43 700
- Dimensions (W × H × D) ....................................................................... 96 × 72 × 130 mm
- Front cutout (W × H)...................................................................91 [+1.0] × 67 [+0.7] mm
- Wiring...................................................................................Screw-type terminals 2.5 mm²
- Recommended tightening torque..............................................................................0.5 Nm
use 60/75 °C copper wire only
use class 1 wire only or equivalent
- Weight ............................................................................................................approx. 800 g
Protection-------------------------------------------------------------------------------------------------------
- Protection system.................................................... IP42 from front with correct mounting
IP54 from front with gasket (gasket: P/N 8923-1036)
IP21 from back
- Front foil...................................................................................................insulating surface
- EMC test (CE) ...............................................tested according to applicable EN guidelines
- Listings ........................................................CE marking; UL listing for ordinary locations
UL/cUL listed, Ordinary Locations, File No.: E231544
(no UL/cUL listing for
Packages NU
/
G59N
/
SC+N
)
- Marine-Approval ............................................................................................................ GL