Manual 26004
721DSC for Marine Propulsion Application
Woodward
35
Chapter 7
Major Alarm and Minor Alarm
Major Alarm
If the 721 control detects a major alarm, it will activate the major alarm relay and drive the
actuator output to 0 mA to shut down the engine. If a mechanical reverse-acting actuator is
used with the electronic control, the mechanical governor will take over the engine control.
The condition to cause a major alarm is:
∗
Both speed sensors failed.
CAUTION
The 721 control will not activate a major alarm even on an actuator internal
open-circuit. However, an actuator internal open-circuit will cause engine
shutdown, consequently both speed sensors will fail for engine stalls. This will
then cause the 721 control to activate a major alarm.
Minor Alarm
If the 721 control detects a minor alarm, it will activate the minor alarm relay, but it does not
shut down the engine.
The conditions to cause a minor alarm are:
∗
One speed sensor failed.
∗
KW transducer input signal failed.
∗
Remote Speed Setting input signal failed.
Summary of Contents for 721
Page 6: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 2 ...
Page 8: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 4 ...
Page 12: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 8 ...
Page 16: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 12 ...
Page 38: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 34 ...
Page 40: ...721DSC for Marine PropulsionApplication Manual 26004 Woodward 36 ...
Page 45: ...Appendix P1 ...
Page 46: ...Appendix P2 ...
Page 47: ...Appendix P3 ...
Page 48: ...Appendix P4 ...
Page 49: ...Appendix P5 ...
Page 50: ...Appendix P6 ...