background image

10

Maintenance

Maintenance 

If using one of our Fuel-Saving Modes, be sure to adjust the dates on the

chart below (see chart on page 9 to coordinate the maintenance
schedule with the mode of operation).

• 21 Day Maintenance Cycle - for Optimal Performance

- Refill propane tank.  20 lb (9.07 kg) propane tank lasts

approximately 21 days with 24-hour/7-days operation.

- Replace short-range attractant cartridge.

See Mosquito Magnet

®

attractant label for instructions.

- Empty or replace bug bag.
- Utilize the Quick Clear adapter at every tank change.

• Periodically wipe down the outside of the trap 

with a clean, water damp cloth.

• Charge your battery for 24 hours at the beginning of the season.

Propane Tank Changing Tips

When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand.
When this is done, loosen the knob 1/4 turn, then re-tighten to
maximize seal. 

The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the flow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remove the
regulator from the tank. Re-attach the regulator and try again.

Possible Cause

Maintenance Schedule

Note: Bug bags should be replaced when half full. You can find all your accessory 

needs at your local hardware or home improvement store.

Example

Season 1

Season 2

Season 3

Season 4

Purchase Date
Register Warranty 
Start Up Date

SERVICE:

Seasonal Tune-Up

MAINTENANCE:

Propane, Attractant & Bug Bag Change

Quick Clear Cartridge

Propane, Attractant & Bug Bag Change

Quick Clear Cartridge

Propane, Attractant & Bug Bag Change

Quick Clear Cartridge

Propane, Attractant & Bug Bag Change

Quick Clear Cartridge

Propane, Attractant & Bug Bag Change

Quick Clear Cartridge

SERVICE - WINTERIZATION

Discard Bug Bag & Attractant
Cover Trap Trumpet to avoid

nesting insects

Keep in garage or shed

April 1st
April 1st
April 1st

April 21st
April 21st

May 11th
May 11th

May 31st
May 31st

June 20th
June 20th

July 10th
July 10th

March 15th

9

Smart Technology

Setting Fuel-Saving Modes

The trap has the option to run 24/7 or in one of 4 Fuel-
saving Modes which can extend the life of your
propane tank. The propane tank will last 21 days by
operating your trap 24/7, which is recommended for the
optimal catch rate. Please see the chart below to see
the corresponding propane usage expended based on
the mode of operation. 

Operation

Shut Down

Shut Down

Fuel-Saving Tank Life*

Day Time

Night Time

Mode 1

22 days

1 Hr

1 Hr

Mode 2

24 days

2 Hrs

2 Hrs

Mode 3

27 days

3 Hrs

3 Hrs

Mode 4

30 days

4 Hrs

4 Hrs

* Based on a 20lb. (9.07kg.) propane tank

The Fuel-Saving Mode of operation will stop the
propane use in the middle of the day & during the
middle of the night.  Research has shown mosquito
activity is typically lowest during these time frames.

Note:

Prior to setting your Fuel-Saving modes, your trap must
run 24/7 for 3 full days to allow the “Smart Technology”
system to learn the cycles of day and night. This system
uses a photo sensor to allow the trap to learn and
adjust shut downs based on the shift in sunrise and
sunset as seasons change. 

Fuel-Saving Modes

1. Press the MODE button 

to select the Gas Saver
Mode Setting.

2.

Every time the MODE button is pressed the
Mode will cycle through 1, 2, 3, 4, Off, 1, etc.

3. Mode 1 will shut down the trap 1 hour during the

middle of the day and 1 hour during the middle of the
night. Modes 2, 3 and 4 correspond to 2, 3 and 4
hours of shut down time respectively.

4.

To indicate the trap is in Fuel-Saver
Mode, the arrows will flash and the
green LED light will be off. Additionally,
the Sun element will flash during the

day and the Moon element will flash during the night
when the trap is in Fuel-Saving Mode. The fan will
continue to operate in the trap, at a reduced speed,
to prevent any escape of mosquitoes but will not
capture any additional mosquitoes during this time
frame. 

Cold Temperature Shutdown

The trap has a temperature sensor that will
not allow the trap to start or will automatically
shut down the trap when the outdoor air

temperature is below 50°F (10°C). Research has shown
that there is very little mosquito activity during this time
frame.

If the trap is running (word RUN is visible & Green LED
light on) & the temperature drops below 50°F (10°C) the
trap will shut down. When the trap is in Cool Down
Mode the word COOL and the Thermometer icon will
flash. The trap will restart when the temperature sensor
indicates the air temperature is above 55°F (13°C).

If the trap is in warm up mode it will shut down when
the temperature is below 50°F (10°C) but it will not
restart automatically.

Low Battery Warning

The battery icon and attention will flash if
the battery needs to be recharged.

Child Safety Lock

The ON/OFF button needs to be held for 3 full seconds
to turn-on the trap. 

MODE

Summary of Contents for 1440-655

Page 1: ...For Outdoor Use Only EXECUTIVE 1440 655 ...

Page 2: ...nology Contents Model No Executive Serial No Serial No Type of Gas Propane Manifold Pressure 100 110 psi Minimum Gas Supply Pressure 11 0 in WC Input Rating 759 Btu Hr Minimum Clearances 20 24 Woodstream Corporation 69 North Locust Street Lititz PA 17543 United States www mosquitomagnet com Patents USA Nos 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 6 892 492 7 074 830 7 243 458 7 281 351 an...

Page 3: ...d damage to the cord If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid hazard Visit www mosquitomagnet com Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in ...

Page 4: ...cover i e bushes flowerbeds tree line marshbed Ensure that trap is not directlyagainstanyblockadessuchasbuildings fences etc 4 It is recommended that the trap be placed in the shade 5 Do not place trap directly above a water source sprinklers hose etc 6 Trap must be placed on level ground to avoid tipping or uneven propane distribution 7 For optimal trap placement in your yard refer to the instruc...

Page 5: ... the off season Cover trumpet to prohibit insects from nesting Cover unit with trap cover or with a tarp and secure tightly at the bottom to keep out dust spider webs and other debris NOTE It is recommended that you use the Quick Clear adapter before seasonal storage to avoid build up of contaminants during off season see page 11 READ MANUAL BEFORE STARTING For Optimal Results Run 24 hours day You...

Page 6: ...4 7 which is recommended for the optimal catch rate Please see the chart below to see the corresponding propane usage expended based on the mode of operation Operation Shut Down Shut Down Fuel Saving Tank Life Day Time Night Time Mode 1 22 days 1 Hr 1 Hr Mode 2 24 days 2 Hrs 2 Hrs Mode 3 27 days 3 Hrs 3 Hrs Mode 4 30 days 4 Hrs 4 Hrs Based on a 20lb 9 07kg propane tank The Fuel Saving Mode of oper...

Page 7: ...proceed with normal start up of your trap Unscrew the Quick Clear cartridge first then unscrew Quick Clear adapter and discard the spent Quick Clear cartridge Remember to keep the Quick Clear adapter for future use To start cleaning process while holding Quick Clear Adapter in place unscrew the Quick Clear cartridge 1 4 Turn Only While holding the adapter in place screw the Quick Clear cartridge i...

Page 8: ...Manuel de l utilisateur ...

Page 9: ...Woodstream Corporation 69 North Locust Street Lititz PA 17543 United States www mosquitomagnet com Brevets États Unis No 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 6 892 492 7 074 830 7 243 458 7 281 351 et 7 293 387 Canada No 2 265 944 et 2 322 038 Europe No 1 011 324 1 049 373 et 1 432 304 Australia No 726575 et 735984 New Zealand No 335035 et 506403 Singapore No 64595 et 117722 S Africa ...

Page 10: ...ant d installer ou d entretenir le piège Attention Utilisez uniquement le régulateur de pression du gaz fourni avec cet appareil Ce régulateur est réglé pour une pression de sortie de 28 mbar La pression d alimentation minimale du gaz en entrée est de 28 mbar du régulateur Cet appareil n est pas destiné à être installé sur des véhicules de plaisance et ou des bateaux Fermez le gaz au niveau de la ...

Page 11: ...ur qu elle soit bien en place Quand le piège est assemblé le devant de la tête de pompe la trompe devrait se trouver du côté opposé aux roues et du même côté que le socle en U Mettez l ensemble socle et pied sur l endroit et placez la colonne dans l orifice du socle La pile n est pas complètement chargée en usine chargez la avant la première utilisation Soumise à un usage normal une charge dure to...

Page 12: ...lement moins de deux heures 6 Le chargeur de pile est automatique Il se limitera à une charge sans risques une fois que la pile sera complètement chargée Il ne surchargera pas la pile Pour une durée maximum ne pas laisser la pile dans le chargeur pendant des périodes prolongés 7 Une fois que la pile sera complètement chargée déconnectez la du chargeur et replacez la dans le Mosquito Magnet Executi...

Page 13: ...it le sac à insectes Avertissement Toute installation modification ajustement service ou entretien incorrect peut causer des blessures ou des dommages matériels Lisez bien les instructions d installation d utilisation et d entretien avant d installer ou d entretenir cet appareil Attention Le régulateur de pression du gaz fourni avec l appareil doit être utilisé Ce régulateur est réglé pour une pre...

Page 14: ...ateur Quick Clear en place dévissez la cartouche Quick Clear seulement d un quart de tour Tout en maintenant l adaptateur en place vissez la cartouche Quick Clear sur l adaptateur Tout d abord vissez à la main l adaptateur Quick Clear sur la valve Étape 4 Étape 5 Étape 6 Étape 7 Entretien Entretien Si vous utilisez l un des modes d économie de carburant assurez vous bien de définir les dates sur l...

Page 15: ...strée 3 Si une pile complètement chargée indique que la charge est faible pendant le cycle rechargez ou remplacez la pile 1 Défaillance électrique 1 Contactez votre prestataire de service local 1 Vérifiez que la température est constamment au dessus de 50 F 10 C 2 Suivez les étapes de la section Emplacement optimum du piège de votre manuel de l utilisateur ou consultez votre mode d emploi sur le C...

Reviews: