SAFETY
-9-
We do not recommend using an extension cord
for 220V equipment.
Instead, arrange the
placement of your machinery and installed
wiring to eliminate the need for extension
cords. If you must use an extension cord:
•
Make sure it is rated Hard Service (grade S)
or better.
•
The extension cord must always contain a
ground wire and plug pin.
•
Always repair or replace extension cords
when they become worn or damaged.
•
Use at least a 14 gauge cord (preferably 12
gauge).
•
DO NOT use a cord over 25 feet long.
Extension Cords
Grounding
This machine must be grounded! The electrical
cord supplied with the Model W1684 is not
equipped with a 220 volt plug. Use a plug with a
ground pin. If your outlet does not accommo-
date a ground pin, have the outlet replaced by a
qualified electrician or have an appropriate
adapter installed and grounded properly. An
adapter with a grounding wire does not guaran-
tee the machine will be grounded. A ground
source must be verified.
Do not remove the ground-
ing pin from any plug and
always make sure all wiring
to the machine is grounded
before operating. Any elec-
trical outlet and circuit that
you plug your machine into
must be grounded. Serious
injury may occur if this
warning is ignored!