Hardware Reference Guide
SST-DN3-104-1 and SST-DN3-104-2
48
Error
Messages
Document Edition: 1.0, Document #: 715-0082, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
A.1 Introduction
The following errors may be reported during the card’s startup self-test. Error messages are
posted in the Message Area (0x40) of the Host Interface Memory and can be displayed using one
of the status applications, such as DNSTAT, provided with the card.
A.2 FamilyID Messages
If FamilyID reads anything other than 0x40, the card has not been found. To fix the problem,
follow these steps:
1. Double-check the switch settings and make sure they match up with the I/O driver port
address setting in the software application.
2. Make sure you have waited up to 2 seconds after the PC/104 RESET signal has been
negated.
3. Check for an I/O conflict.
4. If you continue to experience difficulties, please refer to Section 4.4,