ELECTRICAL REQUIREMENTS

R

WOODBRIDGE 

WHIRLPOOL & AIR BATHTUB

HEATED AIR MASSAGE TUB, HEATED WHIRLPOOL TUB

3 Total Breakers

RESET

CGFI
Outlet

RESET

CGFI
Outlet

RESET

120V 15AMP
Dedicated
GFCI Breaker

They are 3 Dedicated 120V 15AMP GFCI Breaker on Heated Air Bubble and Whirlpooi Tub

 
 

1. One (1) Dedicated GFCI Breaker for the Whirlpool Pump
2.  One (1) Dedicated GFCI Breaker for the Air Massage Blower
3.  One (1) Dedicated GFCI Breaker for the Heater 

Each application requires a 120V 15AMP Dedicated GFCI Breaker.

RESET

CGFI
Outlet

3 Total Breakers

CGFI
Outlet

RESET

BJ200

BJ300

5-10mm(02"to 0.4")

For Air Bath and Whirpool Tub installation, Do not apply any silicone sealant after 
installation, leave a 5-10mm(0.2" to 0.4")gap for motor/pump ventilation purpose.

RESET

CGFI
Outlet

Air  Blower

  (0.3KW) 

 Heater 

(1.5KW)

Whirlpool Pump

  (

0.75KW)

5-10mm(02"to 0.4")

RESET

CGFI
Outlet

Air  Blower

  (0.3KW) 

Whirlpool Pump

  (

0.75KW)

 Heater 

(1.5KW)

Heater automatically on when pump starts and will automatically 
heat up to 100˚F/38˚

C

Pump  (110V-120V 60HZ 7.5A )                       
Thermostat Heater (110V-120V 60HZ 13.6A)
Air Blower (110V-120V 60HZ 3A)

Heater will stop to heating when water temperature reach 100˚F/38˚C

Summary of Contents for BJ200

Page 1: ...rdance to your location We are not responsible for providing any compliance certi cations Under no circumstances we shall not be liable for any incidental damages sustained in connection with this pro...

Page 2: ...ar installation This will help you avoid costly mistakes In addition to proper installation read all operating and safety instructions All information is based on the latest product information availa...

Page 3: ...ration Position the plumbing according to rough in dimensions Cap the supplies and check for leaks BEFORE INSTALLING UNIT CAUTION Ensure a watertight seal on the bath drain connections A Install the f...

Page 4: ...er two minutes Check the pump and pipes union connections for leaks Hand tighten union connections if required IMPORTANT Your bathtub has been factory tested and approved It is the responsibility of t...

Page 5: ...Dedicated GFCI Breaker R E S E T CGFI Outlet 3 Total Breakers CGFI Outlet RESET BJ200 BJ300 5 10mm 02 to 0 4 For Air Bath and Whirpool Tub installation Do not apply any silicone sealant after install...

Page 6: ...5 NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION 6...

Page 7: ...ully insured and licensed contractor only Installation by anyoneother than fully insured and licensed contractorwillvoid this limited warranty This warranty does not cover surface damaged caused by us...

Page 8: ...urface shine is restored Repair and Maintenance The bathtub must be installed and used as described in this manual Use caution when entering or exiting the bathtub Do not permit children or persons wi...

Reviews: