ELECTRICAL REQUIREMENTS
R
WOODBRIDGE
WHIRLPOOL & AIR BATHTUB
HEATED AIR MASSAGE TUB, HEATED WHIRLPOOL TUB
3 Total Breakers
RESET
CGFI
Outlet
RESET
CGFI
Outlet
RESET
120V 15AMP
Dedicated
GFCI Breaker
They are 3 Dedicated 120V 15AMP GFCI Breaker on Heated Air Bubble and Whirlpooi Tub
1. One (1) Dedicated GFCI Breaker for the Whirlpool Pump
2. One (1) Dedicated GFCI Breaker for the Air Massage Blower
3. One (1) Dedicated GFCI Breaker for the Heater
Each application requires a 120V 15AMP Dedicated GFCI Breaker.
RESET
CGFI
Outlet
3 Total Breakers
CGFI
Outlet
RESET
BJ200
BJ300
5-10mm(02"to 0.4")
For Air Bath and Whirpool Tub installation, Do not apply any silicone sealant after
installation, leave a 5-10mm(0.2" to 0.4")gap for motor/pump ventilation purpose.
RESET
CGFI
Outlet
Air Blower
(0.3KW)
Heater
(1.5KW)
Whirlpool Pump
(
0.75KW)
5-10mm(02"to 0.4")
RESET
CGFI
Outlet
Air Blower
(0.3KW)
Whirlpool Pump
(
0.75KW)
Heater
(1.5KW)
Heater automatically on when pump starts and will automatically
heat up to 100˚F/38˚
C
Pump (110V-120V 60HZ 7.5A )
Thermostat Heater (110V-120V 60HZ 13.6A)
Air Blower (110V-120V 60HZ 3A)
Heater will stop to heating when water temperature reach 100˚F/38˚C