12"
Maximum
Depth
11"Minimum
72" Minimum
Minimum 7"
From Both
Side Walls
CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does, it is
considered a mantel and must meet the mantel requirements listed in this manual.
Figure 6 - Clearances
Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or noncombustible material panel extending full width and depth of
the appliance.
WARNING
Clearance to
Combustibles
Sides
0
Floor
0
Back
0
Standoffs
0
Front
36"
NOTE: When using a Woodbridge
Fireplace steel facing, a non-
combustible material must extend
1" beyond the facing. Combustible
materials may be brought right to the
fireplace top and sides at the front
when no steel facing is used.
11