Cautions & Warnings (Cont'd.)

Professional Series Grill  Installation and Operation Manual

INSTALLATION IN A ROOFED AREA

If installed within an outdoor structure incorporating a roof, a suitable, non-combustible means of 

capturing the heat and smoke from the grill and exhausting it safely above the roof structure is required. 

The venting system must be suitable for high temperature solid fuel applications. It may also require a fan 

suitable for high temperature solid fuel applications. The venting system must include an approved spark 

arrestor device at the outlet above the roof. The venting system will typically  incorporate a metal corro-

sion resistant hood suitable for high temperatures and overhanging all sides of the appliance sufficiently 

to capture the smoke and heat coming off of the appliance. The appliance may also be placed within a 

masonry structure designed to capture the heat and smoke and incorporating a chimney to 

discharge the exhaust safely above the roof structure. The venting system must be designed  and installed 

by a qualified installer/contractor. We recommend you consult with a fireplace or HVAC professional 

experienced with solid fuel applications. The venting system must be designed, installed and maintained 

in accordance with all applicable local codes and regulations. In the absence of local codes, relevant Na-

tional Codes shall be referred to.

When using the appliance out in the open, beware that sparks and embers can become airborne in the 

course of operating the appliance. To avoid risk of fire, only operate the appliance in a safe area where 

sparks or embers cannot land on vegetation, other flammable materials, or structures. Never use this 

appliance when a burn ban is in effect, and always observe any burning restrictions that may be in place in 

your area. Use common sense and be extremely cautious when conditions are dry and/or windy.

If installing in an area prone to wind, it is highly recommended that a non-combustible wind screen be 

constructed to minimize the effects of the wind while using the appliance.

Keep a fire extinguisher in an easily accessible location near the appliance. 

This unit must be installed and used in accordance with all applicable local codes and regulations.

Install only on a non-combustible surface extending 36 inches in all directions beyond the grill. Clearance 

to all combustible materials from front, sides and back of the grill is 36 inches.

The grill must be installed on a solid level surface, capable of safely supporting the weight of the  grill.

DO NOT INSTALL THIS APPLIANCE INDOORS

Please read this entire manual before you install the appliance. Failure to follow instructions may result in 

property damage, bodily injury or even death. Contact your local building or fire officials about restrictions 

and installation inspection in your area. All installations subject to the approval of the local authority 

having jurisdiction.

Summary of Contents for WS-PWG-5426

Page 1: ...5426 enhance your food home lifestyle with a Wood Stone Home Appliance woodstonehome com info woodstonehome com tf 800 578 6836 f 360 734 0223 Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 U S A An ongoing program of product improvement may require us to change specifications without notice Doc no M0325 00 Rev November 2020 ...

Page 2: ...on 1801 W Bakerview Rd Bellingham WA 98226 U S A M0325 00 Rev November 2020 Table of Contents Professional Series Grill Installation and Operation Manual TABLE OF CONTENTS Professional Series Grill 3 Cautions Warnings 4 Specifications 7 Clearances 8 Installation 9 Grill Shelf Installation 10 Fuel Safety 11 Fueling the Grill 12 Maintenance 14 Fuelwood Facts 15 Replacement Parts 16 Limited Warranty ...

Page 3: ...erview Rd Bellingham WA 98226 U S A M0325 00 Rev November 2020 Professional Series Grill INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE PROFESSIONAL SERIES GRILL STONE FIRED COOKING EQUIPMENT WOOD FIRED GRILL INCLUDING COUNTERTOP MODELS ADDITIONAL MANUAL COPIES AVAILABLE UPON REQUEST Professional Series Grill Installation and Operation Manual Shown with optional Stainless Steel Shelves and S...

Page 4: ...iquids well away from this appliance when in use DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS APPLIANCE USE SOLID WOOD FUEL ONLY RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone corp com For prompt responses to service maintenance questions call us at 1 800 988 8103 WARNING Improper installation adjustment alteration service or maintenance can result in ...

Page 5: ...CTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS iii DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE iv DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL v HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS FOR RESIDENTIAL USE TO BE INSTALLED ONLY OUTDOORS CLEARANCES TO COMBUSTIBLES...

Page 6: ...installed and maintained in accordance with all applicable local codes and regulations In the absence of local codes relevant Na tional Codes shall be referred to When using the appliance out in the open beware that sparks and embers can become airborne in the course of operating the appliance To avoid risk of fire only operate the appliance in a safe area where sparks or embers cannot land on veg...

Page 7: ...RPORATION 1801 W BAKERVIEW RD BELLINGHAM WA 98226 360 650 1111 WOODSTONE CORP COM PART NO WS PWG 5426 SIZE B REV 0 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT EXPRESS WRITTEN PERMISSION OF WOOD STONE CORP IS PROHIBITED 6 150mm 16 1 2 420mm 52 1 2 1330mm 1 30mm 1 2 3 4 A B C D 1 2 3 4 PART NO SIZE B T...

Page 8: ...A MAJOR CAUSE OF APPLIANCE RELATED FIRES IS A FAILURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL IT IS OF UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCOR DANCE WITH THESE INSTRUCTIONS SIDES ABOVE if installed under a suitable metal hood or masonry chimney The hood or chimney assembly should extend at least 12 inches beyond the outside perimeter of the grill to ensure ...

Page 9: ...ns without notice DIMENSIONS ARE IN INCHES TOLERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE 1 of 1 Seal bottom edge of flashing to counter using high temp silicone provided Seal any gap between the flashing and the charbroiler using the high temp silicone provided Using the hardware provided install the stainless steel flashing to the front and back of the charbroiler Install Sacrificia...

Page 10: ... GRILL 1 The optional Broiler Shelf Stand is lowered onto the Professional Series Grill so that the legs slide over the side walls The broiler shelf must be re moved to install the stainless steel rain cover Allow shelf to cool before removing 1 of 1 INSTALL RACKS ONTO STAND 2 Place the Wire Cooking Rack Supports onto the upper or lower bottom supports 3 Place the lower Wire Cooking Racks onto the...

Page 11: ...and handled in accordance with the recommendations outlined in NFPA 96 DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from the combustible materials pending final disposal When the ashes are disposed by burial in soil or otherwise locally dispersed they shoul...

Page 12: ...s out of the intense start up fire heat and to create working space 2 Using the Ash Shovel remove about 2 3rds of the fly ash Move ash and any live coals along the back center of the fire box The coals and ash will help start the new fire faster LUMP CHARCOAL AND WOOD FIRE 4 Stack 3 or 4 small pieces of wood in a conical tepee shape on top of any live coals towards the back of the fire box Ignite ...

Page 13: ... Tool to distribute the coals in the firebox with about 3 deep in the back tapering to 1 1 2 deep in the front 8 To optimize heat and energy pull live coals forward out of the fire Do not pull wood with open flame forward Cooking over an open flame tends to burn fat making food taste bitter 6 6 8 8 7 7 MAINTAINING THE FIREBOX 7 Place two medium pieces of wood on either side of the center flame eve...

Page 14: ...toring it inside of any structure CREOSOTE FORMATION AND NEED FOR REMOVAL If using any type of chimney hood or venting system above the appliance regular inspection and cleaning is required Any creosote buildup must be removed to reduce risk of fire When wood is burned slowly it pro duces tar and other organic vapors that combine with expelled moisture to form creosote The creosote va pors condens...

Page 15: ... residue which accumulates on the flue lining and exhaust hood increasing the risk of fire Wood should be stored off the ground and out of the rain in an environment that allows good air circulation so the drying process can continue follow the recommendations in NFPA 96 for safe wood storage and handling practices Wet wood is the most common operational difficul ty associated with wood fired cook...

Page 16: ...TED rogram of product improvement may require us to fications without notice 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES NCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE a Desktop 001 5SFB_Mt_St_Helens_SFB_Floor_Mount 1 dft The drawing below indicates part numbers for the replaceable parts on all Mt St Helens models See table for specific model grate capacities and grate part...

Page 17: ...acking due to expansion and contraction stress relief in the ceramic firebox 9 In the event that pressed log products of any type have been burned in the equipment 10 Damage resulting from the use of chemical cleaning products in the appliance as well as any damage from liquids or chemicals including water being poured or sprayed into the appliance If any oral statements have been made regarding t...

Page 18: ...PG 18 OF 20 M0325 00 NOVEMBER 2020 This page left blank with intention ...

Page 19: ...PG 19 OF 20 M0325 00 NOVEMBER 2020 This page left blank with intention ...

Page 20: ... Free 800 578 6836 Fax 360 734 0223 woodstonehome com info woodstonehome com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...