Gas Solenoid Service
1.
Remove retainer "C-clip" on top of valve stem.
2.
Slide coil off of valve stem.
3.
Install new coil onto valve stem.
4.
Re-attach retainer "C-clip" on top of valve
stem.
Gas Valve Service
1.
If entire valve needs replacement, either remove
pressure manifold or remove gas tube(s) from
appropriate valve.
2.
(3) of the 1/4" DC valves can be rotated on their axis
and removed from manifold.
3.
Remaining 1/4" DC valve requires the main manifold
to be removed.
Gas Valve
Gas Valve
(x4)
NOTE: Valves must
be angled as shown
Regulator
PL-4836
VERSION 2 & 3:
POST JUNE 2013
1/2" AC Gas Solenoid Valve
1/4" DC Gas Solenoid Valve