Page 1: ...dstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA GAS PLANCHA Speciality Equipment Countertop Model and Optional Stand Models 4 ZONE GAS PLANCHA WS GPL 4836 4 CT DOC NO M0202 00 REVISED January 2017 Installation and Operation Manual ...

Page 2: ...ion 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 2 M0202 00 January 2017 TABLE OF CONTENTS TABLE OF CONTENTS PLANCHA 3 CAUTIONS AND WARNINGS 4 GPL 4836 4 SPECS COUNTERTOP MODEL 5 GPL 4836 4 SPECS OPTIONAL STAND MODEL 6 CLEARANCES 7 UTILITY INFORMATION 8 BASIC OPERATION 9 DAILY USE MAINTENANCE 10 TROUBLESHOOTING 11 OPERATIONAL SEQUENCE 12 GPL ...

Page 3: ...listed to ANSI Z83 11 2016 CSA 1 8b 2016 Ed 4 and to NSF ANSI Standard 4 2009e PLANCHA WS PL 4836 4 CT Shown with optional stand WS PL 4836 4 CT ANSI Z83 11 2016 Ed 4 CSA 1 8 2016 Ed 4 ANSI NSF STD 4 INSTALLATION AND OPERATION MANUAL WOOD STONE GAS PLANCHA WS GPL 4836 4 CT WS GPL 4836 4 CT ON OPTIONAL STAND ADDITIONAL COPIES AVAILABLE UPON REQUEST ...

Page 4: ... INSPECTION IN YOUR AREA WOOD STONE GAS PLANCHA INSTALLATION AND OPERATION INSTRUCTIONS DO NOT THROW THIS MANUAL AWAY RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual and prompt responses to service maintenance questions are available from Wood Stone 1 800 988 8103 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR A...

Page 5: ... 1 2 520mm 7 1 2 190mm 12 3 4 330mm 4 100mm 34 1 4 870mm 24 1 4 610mm 8 200mm 48 1220mm 39 990mm 2 1 4 60mm G G 12 1 2 320mm GREASE RESERVOIRS MAIN POWER SWITCH GPL 4836 Visibile Controls No Cart 45 1 4 1150mm 21 530mm 8 3 4 220mm 4 1 4 110mm 20 1 2 520mm 7 1 2 190mm 12 3 4 330mm 4 100mm 34 1 4 870mm 24 1 4 610mm 8 200mm 48 1220mm 39 990mm 2 1 4 60mm G G 12 1 2 320mm GREASE RESERVOIRS MAIN POWER S...

Page 6: ...00mm 24 1 4 610mm 34 1 4 870mm 2 1 4 60mm G G 12 1 2 320mm 42 3 4 1090mm 6 150mm 1 1 4 30mm MAIN POWER SWITCH GREASE RESERVOIRS Side view GPL 4836 Visible Controls With Cart 22 1 2 570mm 42 3 4 1090mm 16 1 2 420mm 7 3 4 200mm 29 1 2 750mm 37 3 4 959mm 35 1 4 890mm 7 1 2 190mm 26 1 2 670mm 39 990mm 48 1220mm 8 200mm 24 1 4 610mm 34 1 4 870mm 2 1 4 60mm G G 12 1 2 320mm 42 3 4 1090mm 6 150mm 1 1 4 3...

Page 7: ...k and 0 inch clearance to non combustible construction from sides and back 2 This appliance may be installed on a combustible or non combustible surface 3 Combustion air Combustion air flows into the Plancha through vents in the bottom panel The Plancha must be installed with the legs provided Do not block the space between the appliance and the countertop IFTHIS EQUIPMENT IS NOT PROPERLY INSTALLE...

Page 8: ...a to run on a different gas type i e NG to LP please contact Wood Stone to obtain the necessary parts and instructions No modification is required for use at high altitudes ELECTRICAL RATINGS The Plancha is equipped with a NEMA 5 15P plug for use with a standard 120 VAC 15 A or 20 A outlet Model Natural Gas NG model Propane LP model GPL 4836 4 CT 4 0 W C 9 0 W C Model Natural Gas NG model Propane ...

Page 9: ...ce utilizes an automatic ignition system there are no standing pilots to manually light Press the Power Switch to the OFF position to turn off the Plancha At start up the red RESET light next to the Power Switch will be illuminated until the automatic ignition system has successfully lit the pilot This is typically not more than a few seconds However when initially starting the unit up after insta...

Page 10: ...grill surface first shut down the Plancha and allow it to cool If the Plancha is too hot the chemical may tend to boil or burn off immediately and not work as effectively Do not pour water onto a hot Plancha to cool it as this can warp the cook surface DO NOT USE EXCESSIVE AMOUNTS OF WATER TO CLEAN THE PLANCHA Be careful when using scrapers on the cook surface to avoid scratching or gouging the to...

Page 11: ... is turned on To retry turn off Plancha wait 5 minutes then turn back on 2 If the Plancha is being started for the first time Make sure all air has been bled from the gas line 1 Determine the cooking surface temperature using the Surface Temperature Measurement Procedure below 2 If any reading is outside the acceptable temperature range call Wood Stone Please contact Wood Stone at 1 800 988 8103 s...

Page 12: ...ION Based upon the temperature of each of the four zones as compared to the Set Point individual Burners are ON or OFF Burners light Controller determines temperature is below Set Point and signals Burners to light Green front panel lights illuminate Software version blinks on one of the green front panel lights and momentarily illuminates the red Fault light Burner s do not light After 3 attempts...

Page 13: ...on 4 Knob Alarm 24 Z2 Z3Z4 Z2 Z3Z4 Z2 Z3Z4 W6 P2 W6 P3 W6 P4 OR BK BK WH RD Z2 Z3 Z4 1 4 Q C Z1 TYP X4 A 24 Th Valve Burner Gnd 1 2 3 4 5 6 7 8 9 W6P1 Valve 1 2 3 4 5 6 7 8 W6P5 W6 TB1 W6 TB3 W6 TB2 BK WH RD OR GY OG RD Note Connector Clip Orientation Wire Side View 1 4 x 0 032 Q C Gas Valve P N 7000 1321 Fenwal Ign Controller Woodstone Corp P N 7000 1695 7000 1725 TYP X3 H V Suppression Cable 700...

Page 14: ... 5 6 7 8 9 10 11 12 J1 J3 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 Woodstone Corp P N 7000 1762 1 TB1 W11 A1 J1 J5 10 9 8 7 6 5 4 3 2 1 CPI Board Woodstone Corp P N See Sheet 3 TB1 L N G Jumper Terminal 7000 1610 Conduit Woodstone Corp P N 7000 1370 W11 off off 3 2 1 4 9 1 3 8 Woodstone P N 7000 0946 1 S1 3 2 1 3 2 1 S1 Rear Connector Plate DS5 Silver Gold Red 7000 0897 7000 1725 BK BK 70CE...

Page 15: ... 10 J3 Woodstone Corp P N 7000 0891 61 Pot 2 CW 5v Pot 2 Wiper 0 5v Pot 2 CCW gnd LED 2 switched LED 2 24 Pot 4 CW 5v Pot 4 Wiper 0 5v Pot 4 CCW gnd LED 4 switched LED 4 24 LED 3 24 LED 3 switched Pot 3 CCW gnd Pot 3 Wiper 0 5v Pot 3 CW 5v LED 1 24 LED 1 switched Pot 1 CCW gnd Pot 1 Wiper 0 5v Pot 1 CW 5v A1 CPI Board DS2 DS1 RD BU WH YE WH BK WH RD BU RD YE BU RD BU GY BU PK YE PK OG GY YE BU RD ...

Page 16: ... 3 4 5 6 7 8 9 10 11 12 J1 J3 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 Woodstone Corp P N 7000 1762 1 TB1 W11 A1 J1 J5 10 9 8 7 6 5 4 3 2 1 CPI Board Woodstone Corp P N See Sheet 3 TB1 L N G Jumper Terminal 7000 1610 Conduit Woodstone Corp P N 7000 1370 W11 off off 3 2 1 4 9 1 3 8 Woodstone P N 7000 0946 1 S1 3 2 1 3 2 1 S1 Rear Connector Plate DS5 Silver Gold Red 7000 0897 7000 1725 BK BK ...

Page 17: ......

Page 18: ......

Page 19: ...ormal conditions 7 Scratches or damage to the grill surface due to improper cleaning or normal wear and tear If any oral statements have been made regarding this appliance such statements do not constitute warranties and are not part of the contract of sale This Limited Warranty constitutes the complete final and exclusive statement with regard to warranties THIS LIMITED WARRANTY IS EXCLUSIVE AND ...

Page 20: ...3 Tel 360 650 1111 Fax 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...