OPERATIONAL SEQUENCE
SEQUENCE OF OPERATION
Based upon the temperature
of each of the four zones as
compared to the Set Point,
individual Burners are
ON or OFF�
Burners light�
Controller determines
temperature is below Set Point
and signals Burners to light�
Green front panel lights
illuminate�
Software version blinks on one of
the green front panel lights, and
momentarily illuminates the red
"Fault" light�
Burner(s) do not light� After 3 attempts, Gas
Valve closes and red Fault light illuminates�
No additional attempts at relighting until
Main Power is turned OFF, then ON to reset�
Power Switch ON�
Power OFF� All Gas Valves
close� All Burners and
Controller OFF�