background image

17

Whatcom Gas-Fired Vertical Rotisserie 

Installation and Operation Manual

120 VAC ELECTRICAL DIAGRAMS

120 VAC MODELS

This electrical schematic diagram can also be found affixed to the inside of the rear service panel of the rotisserie�





























































































    

    

    

    





























































































































































































Summary of Contents for WHATCOM WS-GVR-10

Page 1: ... Vertical Rotisserie WHATCOM WS GVR 10 Installation and Operation Manual woodstone corp com Revised January 2014 Doc no M0056 00 wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 ...

Page 2: ...stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS WHATCOM ROTISSERIE 3 CAUTIONS AND WARNINGS 4 GVR SPECIFICATIONS 6 GVR CT SPECIFICATIONS 7 CLEARANCES UTILITIES 8 VENTING 9 UTILITY CONNECTIONS 10 GAS INFORMATION 11 COMPONENT LAYOUT 12 CONTROLS 13 OPERATION 14 MAINTENANCE REPAIR 15 120 VAC ELECTRICAL DIAGR...

Page 3: ...fo woodstone corp com or visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 WHATCOM ROTISSERIE Shown GVR 10 INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE WHATCOM VERTICAL ROTISSERIE GAS FIRED ROTISSERIE GVR 10 NG LP DD AND GVR 10 NG LP DD CT MODELS ADDITIONAL COPIES AVAILABLE UPON REQUEST WHATCOM ROTISSER...

Page 4: ...YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Also always keep the area under and around this appliance free and clear of any and all combustible materials It is recommended that this oven be installed maintained and serviced by authorized professionals READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THE APPLIANCE Ple...

Page 5: ...ard 4 2009 WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment When the rotisserie is not properly installed a fire may result To reduce the risk of fire follow the installation instructions WARNING This product m...

Page 6: ...111 www woodstone corp com DIMENSIONS ARE IN INCHES TOLERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE HE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE ITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT MAY REQUIRE US TO CHANGE SPECIFICATIONS WITHOUT NOTICE...

Page 7: ... BTU LP GD C 1 1 2 GREASE DRAIN 1 4 NPT COLD WATER FITTING 1 of 1 FRONT VIEW AIR INTAKE SIDE VIEW G C AIR INTAKE REAR VIEW PLAN VIEW 36 910mm 32 1 4 820mm R 26 3 4 680mm Door Swing 26 3 4 680mm 25 1 4 640mm 43 1 2 1110mm 5 1 4 130mm 15 380mm 3 70mm G C 27 1 2 700mm 30 760mm GD AIR INTAKE AIR INTAKE AIR INTAKE AIR INTAKE BOTTOMVIEW 5 3 4 140mm 7 180mm 4 1 4 110mm 3 80mm 2 1 2 70mm 2 1 2 60mm REV LE...

Page 8: ...ate quick disconnect supplied by others to attach the gas supply to the 3 4 FNPT gas inlet A readily accessible gas shut off valve should be provided on the gas supply line to the rotisserie ELECTRICAL 120 VAC 1 3 A 60 Hz or 240 VAC 4 A 60 Hz Detachable cord set NEMA 5 15 plug is supplied with the unit Supply a grounded 3 prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG WATE...

Page 9: ...tandard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 96 The hood should completely cover and extend a minimum of 6 inches beyond the edge of the rotisserie on all sides IT IS NEVER APPROPRIATE TO USE B VENT IN ANY PART OF AN EXHAUST SYSTEM CONNECTED TO THIS ROTISSERIE VERY IMPORTANT WOOD STONE RECOMMENDS THAT YOU SUBMIT VENTING PLANS TO LOCAL CODE AUTHORITIES B...

Page 10: ...rs for Movable Gas Appliances ANSI Z21 69 or CAN CGA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 or CAN 1 6 9 ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its as...

Page 11: ...s supply piping system by closing its individual manual shutoff valve supplied by others during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 psi 3 45 kPa GAS HOOK UP The Whatcom Rotisserie is equipped with a 3 4 inch FNPT gas inlet connection Have a licensed gas installer provide the hook up and test all fittings and pipe connections for leaks Use...

Page 12: ...6 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 COMPONENT LAYOUT SV 1 gas valve flame post SV 2 gas valve left IR burner SV 3 gas valve right IR burner Circuit breakers Electrical assembly Drive motor Door switch rear door models only Wiring diagram attached to inside of right side as viewed from front access panel Electrical diagrams are also in the ELECTRICAL DIAGRAM section of this manual R...

Page 13: ...poration 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 CONTROLS Controls located on the back to upper right of the doors on models with optional rear door START STOP JOG IR WATER NOTE Pressing the RED stop button at any time will stop drum rotation and turn off the burners FRONT CONTROLS REAR CONTROLS WITH OPTIONAL REAR DOOR Jog Start NOTE Opening the re...

Page 14: ...the top of the rotisserie interior The total combined load of all the spits should not exceed 75 lbs Hang the spits so that the load is distributed evenly Use the JOG button green button near the center of the front panel as necessary to rotate the drum when hanging the spits On units equipped with a rear door there is also a JOG button located on the back next to the door The drum will turn only ...

Page 15: ...LASS Use a mild detergent or appropriate glass cleaner to clean the glass Do not use any abrasive cleaners or pads on the glass doors CLEANING THE ACCESSORIES All rotisserie attachments spits forks etc should be cleaned between uses using an approved mild detergent hot water and sanitizing agent Alternatively these items can be cleaned in a dishwasher ROUTINE PREVENTATIVE MAINTENANCE Clean the rot...

Page 16: ...cal Rotisserie Installation and Operation Manual 120 VAC ELECTRICAL DIAGRAMS 120 VAC MODELS This electrical schematic diagram can also be found affixed to the inside of the rear service panel of the rotisserie ELECTRICAL DIAGRAM ...

Page 17: ...red Vertical Rotisserie Installation and Operation Manual 120 VAC ELECTRICAL DIAGRAMS 120 VAC MODELS This electrical schematic diagram can also be found affixed to the inside of the rear service panel of the rotisserie ...

Page 18: ...red Vertical Rotisserie Installation and Operation Manual 240 VAC ELECTRICAL DIAGRAMS 240 VAC MODELS This electrical schematic diagram can also be found affixed to the inside of the rear service panel of the rotisserie ...

Page 19: ...red Vertical Rotisserie Installation and Operation Manual 240 VAC ELECTRICAL DIAGRAMS 240 VAC MODELS This electrical schematic diagram can also be found affixed to the inside of the rear service panel of the rotisserie ...

Page 20: ...pment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sprayed into the oven If an...

Reviews: