PG
8
OF
36
M0324.00 APRIL 2020
Traditional Series CE
Installation and Operation Manual
INSTALLATION CLEARANCES
Installation and servicing of this product could expose you to glasswool/ceramic fibers as well as
calcium silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR
SERVICING THIS APPLIANCE. Please read this entire manual before you install the oven. Failure to follow
instructions may result in property damage, bodily injury or even death. Contact your local building or
fire officials about restrictions and installation inspection in your area.
CLEARANCES
1.
The Wood Stone Mountain Series oven must have a
minimum 25 mm (1") clearance to combustibles from all sides, and
152 mm (6") clearance to combustibles from the top. If building materials will contact the oven, they must be completely non-
combustible. Please note that standard Drywall (or Sheetrock) is considered a combustible. When non-combustible building
materials contact the body of the oven, the respective clearances are transferred to those non-combustibles.
2.
Any facade 152 mm (6") to either side of the oven doorway or above, must be constructed of non-combustible building
materials
.
3.
For gas-only models
, this oven is suitable for installation on combustible floors.
For gas/wood combination models
, this oven is suitable for installation on combustible floors. The minimum hearth
extension area to be covered with a non-combustible floor surface must extend 914 mm (36") in front of and 762mm (30") to
either side of the oven door opening.
NOTICE:
Only non-combustible materials may be applied directly to the oven. For stucco-ready appliances (model numbers
including an “-S”), the same clearances as described above apply. Non-combustible stucco mix must be used and applied to a
minimum thickness of 25 mm (1").
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
WARNING:
DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN. FAILURE TO FOLLOW INSTRUCTIONS MAY
RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT YOUR LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.